4 Care and maintenance
17
4.3 Cleaning and replacing the long-life activated charcoal
filter
The long-life activated charcoal filter can be cleaned and reactivated. The
long-life activated charcoal filter should be changed ever month with normal
use or whenever the indicator illuminates. The filter can be cleaned in
a dishwasher at 65 °C (select an «intensive» or «heavy soil» wash
programme). Wash the filter separately so that it does not become clogged
with food particles. If it is not possible to wash the filter in a dishwasher, soak
the filter in 60 °C water and detergent for one hour. Then rinse well. To
reactivate the activated charcoal, dry the filter without the frame in the oven.
Select top and bottom heat or hot air and set the temperature to 100 °C.
Place the filter on a wire shelf and allow to dry for 60 minutes.
Remove and clean the grease filter.
Remove the long-life activated charcoal filter 1
from the bottom.
Remove, clean, reactivate and replace the filter 2
back into the frame 3. Take care not to damage
the filter. If necessary, replace the used long-life
activated charcoal filter by a new one.
Replace the long-life activated charcoal filter 1.
Replace the grease filter.
After cleaning, hold the button depressed
for at least 5 seconds.
The display goes out.
Long-life activated charcoal filters are only used in the recirculation
model.
The long-life activated charcoal filter needs to be replaced after about
3 years as its ability to absorb odours declines. The spent long-life
activated charcoal filter can be disposed of in the household waste.