Performance Data Sheet
Hotpoint SmartWater Filtration System
HWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
'100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter
Chlorine
T&O
Particulate**
Parameter
USEPA
MCL
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Awazine
2,4-D
Asbestos
Influent
Challenge
1.9 ppm
200,000
Effluent
Average Maximum
0.02 ppm 0.05 ppm
3,978 7,800
% Reduction
Average Minimum
98.90% 97.37%
98.00% 96.10%
USEPA
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
99%
Standard No. 53: Health Effects
Influent Effluent
Average
0.07 NTU
26
1 ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.042 ppm
0.32 MFL/ml
Maxinlllln
0.1 NTU
55
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.090 ppm
1.2 MFL/ml
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0.272 ppm
690 MFL/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
84.89%
99.95%
* Testedusing a flow rate of 0.5 gpm; pressure of 120psig; pH of Z5-+0,5;temp. of 20-+2.5C
** Measurement #7partioles/ml
*** NTU = Nephelometrio Units
% Reduction
Minimum
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Operating Specifications
_ Capacity: certified for up to 300 gallons (1135 1); tip to six months for models without a replacement filter indicator
light; tip to one year for models with a replacement filter indicator light
_/_Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
NTemperature: 33-100 F (0.6-38 C)
_Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
N/Flush new cartridge at full 1low 1or 3 minutes to purge out trapped ain
_ Replace cartridge when flow becomes too slow.
Special Notices
_/Installation instructions; parts and service availability; and standard warranty are included with the product when shipped.
_This drinking ,a-ater system must be maintained according to manufacturer's instructions, including replacement of
filter cartridges.
_Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified 1or cyst reduction may be used on disinfected water that may contain filterable cysts.
NThe contaminants or other substances removed or reduced by this water treatment system are not necessarily in ),our water.
_ Check 1or compliance with the state and local laws and regulations.
System 'Ik'sted and Certified by NSF international against ANSI/NSF
Standard 42 & 53 for the reduction of:
Stamdard No. 42: Aesthetic Effects
Chemical Unit
'l_,_ste and Odor Reduction
Chlorine Reduction, (;lass i
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction