P48NGGGG Southbend 48 Inch Commercial Griddle

User Manual - Page 6

For P48NGGGG.

PDF File Manual, 8 pages, Read Online | Download pdf file

P48NGGGG photo
Loading ...
Loading ...
Loading ...
PLATINUM SERIES RANGE
OWNER’S MANUAL 1185836 REV 8 (9/14)
PAGE
7
OF 47
OPERATION
DANGER
EXPLOSION HAZARD
In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call the emergency
phone number of your gas supplier.
CAUTION
If a pilot ame pilot should go out, the ow of gas to the corresponding burner is NOT interrupted. Consequently, it
is the responsibility of the operator to check the ignition of each burner immediately EVERY TIME a burner is turned
on. Should ignition fail after 10 seconds, turn off the burner, wait 5 minutes, and then try again.
LIGHTING AFTER GAS HAS BEEN SHUT OFF
When turning on the main gas supply to a sectional range, do the following:
1. Make sure that all the control knobs and power switches of all the connected appliances are in the OFF position.
2. Turn on the gas-supply shut-off valve(s).
3. Light the standing pilots of each connected appliance.
4. Light the ovens of the sectional range rst, then wait six minutes before turning on the top sections.
This enables all air to be purged from the sectional-range gas piping.
SHUTDOWN OF ENTIRE RANGE
To place the range in a standby state (ready for use), Oven bases with the electronic ignition option, turn all burner
control knobs to OFF, set all thermostats to their lowest position, and switch all ovens OFF. The pilots will remain lit.
On the standing pilot units, same as above except turn thermostat knob to the “OFF” position. The pilots will remain lit.
To completely shut down the range for an extended period (or prior to disconnecting the gas supply), place the range
in a standby state (as described in the previous paragraph), then turn OFF the manual shut-off valves of all gas supply
connections. This will extinguish the pilots.
OPERATION
Loading ...
Loading ...