Wiring requirement
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
WARNING
fire, or electrical shock.
Recommended Grounding Method
To contact a qualified .electrical installer
It is the customers responsibility:
To assure that the electrical installation is
adequate and conforms to the Nation Electrical
Code,ANSI/NFPA 70-last edition,and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
Nation Fire Protection Association
1 Batterymarch Park
Quincy,Ma 02169-7471
www.nfpa.org
This
conditioner is equipped with a power supply cord with a
three-prong grounding plug. The cord must be plugged
into a mating, grounded three-prong outlet, grounded in
accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's
responsibility to have a properly grounded three-prong
outlet installed by a qualified electrical installer.
air conditioner must be grounded. This air
NOTE:
Your air conditioners device may
differ from the one shown.
To test your power supply cord:
1.Plug power supply cord into a grounded 3prong outlet.
2.Press RESET (on some devices, a green light will turn on).
3.Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4.Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The
power supply cord is ready for operation.
NOTE:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
A.Test button
B.Reset button
TEST
RESET
A
B
This room air conditioner
is equipped with a
power supply cord
required by UL. This
power supply cord contains
state-of-the-art
electronics that sense leakage current. If
the
cord is
crushed, the
electronics detect leakage current and power will be
disconnected in a fraction of
a second.
Power Supply Cord
Electrical Requirements
INSTALLATION REQUIREMENTS
Power supply
Model
Time-delay fuse
(or circuit breaker)
115V
103.5V min.
126.5 V max.
5K BTU DOE
6K BTU DOE
10A
13A
12K BTU cooling only
14K BTU cooling only
8K BTU cooling&heating
15A
6K
BTU
E-star
8K BTU cooling only
10K BTU cooling only