14 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Courtyard Owner’s Manual • 4608-900 Rev. F • 01/19
Pilot lights but continues
to spark, and burner will
not ignite. (If the pilot
continues to spark after
the pilot ame has been lit, 
ame rectication has not 
occurred.)
A short or loose connection in
ame sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify
connections are not grounding out to metal chassis, pilot
burner, pilot enclosure or screen if present, or any other
metal object.
Poor ame rectication or 
contaminated ame sensing 
rod.
Verify correct pilot orice is installed and gas inlet is set 
to  pressure specications.  Check pilot for soot.  Clean if 
necessary.
Module is not grounded.
Verify module is securely grounded to metal chassis of
appliance.  Verify that wire harness is rmly connected to 
the module.
Damaged pilot assembly or
contaminated ame sensing rod
Verify that ceramic insulator around the ame sensing 
rod is not cracked, damaged, or loose. Verify connection
from ame sensing rod to white sensor wire. Polish 
ame sensing rod with ne steel wool to remove any 
contaminants that may have accumulated on ame 
sensing rod. Verify continuity with a multimeter with
ohms set at lowest range. Replace pilot if any damage is
detected.
Module
Turn wall control to OFF position. Remove ignitor wire “I”
from module. Turn wall control to ON position. If there is
no spark at “I” terminal module must be replaced. If there
is a spark at “I” terminal, module is ne.
IntelliFire™ Ignition System (Continued)
Pilot sparks, but will not
light.
Pilot shield covered with media.
Verify that the pilot shield is clear of all media. If
covered, remove media and restart.
Gas supply.
Verify that incoming gas line ball valve is “open”. Verify
that inlet pressure reading is within acceptable limits.
Ignitor gap is too large.
Verify gap of igniter to right side of pilot hood. The gap
should be approximately .17 in. or 1/8 in. (3 mm).
Module is not grounded.
Verify module is securely grounded to metal chassis of
appliance.
Pilot valve solenoid
Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid
from module. If below 1.5 volts, replace module. If 1.5
volts or greater, replace valve.