Majestic SB80 Biltmore Series Natural Vent Woodburning Fireplace

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification
  • MAJ SB80 SB80HB Biltmore WB Specs - (English) Download
  • Specification Sheet - (English) Download
Other Documents Installation Instruction
SB80 photo

Owner’s Manual

This is the main product document for model SB80.

The file format is pdf, 24 pages, you can download this manual here .

background
1
WOODBURNING FIREPLACE
Fire Risk.
WARNING
For use with solid wood fuel only.
Other fuels may overre and generate
poisonous gases (i.e. carbon monoxide).
Model(s):
DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
•
DO NOT overre. Overring will void your
warranty.
Comply with all minimum clearances to com-
bustibles as specied. Failure to comply may
cause house re.
WARNING: If the information in these
instructionsisnotfollowedexactly,are
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Operation and Care
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high temperatures.
Hightemperaturesmayigniteclothingorotherammable
materials.
Keep clothing, furniture, draperies and other ammable
materials away.
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Installation and service of this
appliance should be performed by
qualied personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
SB60, SB60HB
SB80, SB80HB
background
2
Safety Alert Key:
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the replace or to property.
Table of Contents
1 Welcome
A. Congratulations 3
B. LIMITED LIFETIME WARRANTY 4
2 ProductSpecicandGeneralInformation
A. Appliance Certication 6
B. Vented Gas Log Sets, Gas Inserts, Gas Log Lighters, Wood-
burning Inserts 6
3 Important Safety and Operating Information
A. Fireplace Safety 7
1. Clear Space 7
2. Grate 8
3. Refractory 8
4. Firescreen 8
5. Flue Damper 8
6. Glass Doors 8
7. Over-Firing Your Fireplace 8
8. Chimney Fire 8
B. General Operating Parts 9
1. Flue Damper 10
2. Outside Air 10
3. Glass Doors 10
C. Fuel 11
1. Hardwood vs. Softwood 11
2. Moisture content 11
3. Seasoning 12
4. Storing Wood 12
5. Burning Process 12
6. Creosote Formation 12
7. Processed Solid Fuel Firelogs 12
D. First Fire 12
E. Lighting Instructions 13
4 Maintenance and Service
A. Chimney Inspection 14
B. Creosote (Chimney) Cleaning 14
C. Grate 15
D. Glass Cleaning 15
E. Ash Removal 15
F. Refractory 15
5 Troubleshooting
A. FAQs 17
6 Reference Materials
A. Service Parts 19
B. Accessories 23
C. Contact Information 24
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
3
Read this manual before installing or operating this replace.
Please retain this owner’s manual for future references.
A. Congratulations
Listing Label Information/Location
The model information regarding your specic replace can be found on
the rating plate usually located in the control area of the replace.
1
Welcome
Brand: ________________________________________________ Model Name: ___________________________
Serial Number: __________________________________________ Date Installed: __________________________
Fireplace Information:
Local Dealer Information
DEALER: Fill in
your name, address,
phone and email
information here and
replaceinformation
below.
Dealer Name: ________________________________________________________
Address: ____________________________________________________________
____________________________________________________________
Phone: _____________________________________________________________
Email: _____________________________________________________________
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
Congratulations on selecting a HHT wood burning re-
place. The HHT replace you have selected is designed to
provide the utmost in safety and reliability.
As the owner of a new replace, you'll want to read and
carefully follow all of the instructions contained in this
Owner's Manual. Pay special attention to all Cautions and
Warnings.
This Owner's Manual should be retained for future refer-
ence. We suggest that you keep it with your other impor-
tant documents and product manuals.
Your new HHT wood burning replace will give you years
of durable use and trouble-free enjoyment. Welcome to
the HHT family of replace products!
SERIAL NO./NUMERO DESERE
MODEL/MODELE
MFG. DATE
WARNING: RISK OF FIRE DAMAGE. REPLACE GRATE
WITH HEARTH & HOME
TECHNOLOGIES
FIREPLACE ALSO FOR USE
IN MANUFACTURED HOMES
YES
NO
CLEARANCE TO
COMBUSTIBLES:
FIREBOX/
FOYER
IN.
MIN.
FAN KIT/
KIT DU VENTILATUER
MODEL NO.
AMP.
IF INSTALLATION OR OPERATING INSTRUCTIONS ARE MISSING
CONTACT:
HEARTH & HOME TECHNOLOGIES,
7571 215th Street West, Lakeville, MN 55044.
P.N. 4021-954A
FIRE CHAMBER INTENDED FOR USE WITH HEARTH & HOME TECHNOLOGIES
LISTED FIREPLACE PARTS AND GLASS DOOR KITS. SEE INSTALLATION AND
OPERATING INSTRUCTIONS FOR THIS MODEL.
GRATE MODEL/GRILLE MODELE
DEGAGEMENT DES
MATEIAUX COMBUSTIBLES:
MM
MIN.
AVERTISSEMT:RISQUE DE DOMMAGE PARINCENDIE, REMPLACEZ LA GRILLE AVEC
HEARTH & HOME TECHNOLOGIES
CHIMNEY/CHEMNEE
2 IN. MIN.
51 MM
RATED AT/CAPACITE
115 VOLTS, 50/60 HZ
Serial Number
Grate
Fireplace Model
background
4
X Molded refractory panels
4021-645H 10/15 Page 1 of 2
Hearth & Home Technologies
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT
gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership
of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance
will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo-
nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its
obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product
itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty
is subject to conditions, exclusions and limitations as described below.
WARRANTY PERIOD:
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage
begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent,
authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months
following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for
parts and labor for covered components is produced in the following table.
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for
gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These
time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.
See conditions, exclusions, and limitations on next page.
Parts Labor Gas Wood Pellet
EPA
Wood
Coal Electric Venting
XXXXXXX
All parts and material except as
covered by Conditions,
Exclusions, and Limitations
listed
XXX
Igniters, electronic components,
and glass
X X X X X Factory-installed blowers
X Firepots and burnpots
5 years 1 year X X Castings and baffles
7 years 3 years X X X
Manifold tubes,
HHT chimney and termination
10
years
1 year X Burners, logs and refractory
Limited
Lifetime
3 years X X X X X Firebox and heat exchanger
XXXXXXX
All replacement parts
beyond warranty period
Warranty Period HHT Manufactured Appliances and Venting
1 Year
Components Covered
3 years
2 years
90 Days
X
Ignition Modules
B. LIMITED LIFETIME WARRANTY
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
5
WARRANTY CONDITIONS:
This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of
HHT authorized dealers is available on the HHT branded websites.
This warranty is only valid while the HHT appliance remains at the site of original installation.
• This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance
resides.
Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact
the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service
from a dealer other than the dealer from whom you originally purchased the product.
Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges
for parts are not covered by this warranty.
This warranty is void if:
The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging
chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling,
cracking and discoloration of steel or enamel finishes.
The appliance is subjected to prolonged periods of dampness or condensation.
There is any damage to the appliance or other components due to water or weather damage which is the result of, but
not limited to, improper chimney or venting installation.
LIMITATIONS OF LIABILITY:
The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or
implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no
event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states
do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you.
This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO
THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE
EXPRESSED WARRANTY SPECIFIED ABOVE.
WARRANTY EXCLUSIONS:
This warranty does not cover the following:
Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and
exterior surface finishes may occur. This is not a flaw and is not covered under warranty.
Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items,
or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.
Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts
include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass.
Expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints
related to this noise are not covered by this warranty.
Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation
instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to
install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera-
tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/
incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting
caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or
forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7)
installation or use of components not supplied with the appliance or any other components not expressly authorized
and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing;
and/or (9) interruptions or fluctuations of electrical power supply to the appliance.
Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.
Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.
HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa-
tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider-
ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of
the structure.
4021-645H 10/15 Page 2 of 2
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
6
2
ProductSpecicandGeneralInformation
Warning! Risk of Fire!
For use with solid wood fuel only.
Otherfuelsmayoverreandgenerate
poisonousgases(i.e.carbonmonoxide).
B. Gas Log Sets, Gas Inserts, Gas Log Light-
ers, Wood-burning Inserts
Optional.
Vented gas logs sets, gas inserts, gas log lighters, or
wood-burning inserts can be installed in this replace.
Follow the instructions provided with the accessory to
operation.
Unvented Gas Logs
CAUTION! If an unvented gas appliance is installed in
the replace, the gas appliance must only be operated
with the replace glass door fully open (if included).
Only unvented gas log sets which have been found to
comply with the standard for unvented room heaters,
ANSI Z211.11.2, are to be installed in this replace. If
an unvented gas appliance is installed it must incorpo-
rate an automatic shutoff device, and must be installed
in accordance with the National Fuel Gas Code Z223.1,
Latest edition.
WARNING! Do Not operateanunventedgaslogsetinthis
replacewiththechimneyremoved.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
A.ApplianceCertication
This replace may be installed in sleeping rooms. This
replace is not approved for manufactured housing. If in-
stalled with a gas log set, provisions for the National Fuel
Gas Code must be met.
This replace has been tested and listed for use with the
optional components specied in this manual. These op-
tional components may be purchased separately and in-
stalled at a later date. Installation of an outside air kit will
require signicant reconstruction and is best if installed at
the time of replace installation.
This replace system has been tested and listed in accor-
dance with UL 127 and ULC-S610 standards by Underwrit-
ers Laboratories Inc. for installation and operation in the
United States and Canada.
background
7
A. Fireplace Safety
Most problems are caused by improper installation and op-
eration of the replace. To provide reasonable re safety,
the following should be given serious consideration:
The re should be supervised whenever the replace is
in use.
An annual inspection should be performed on the
replace system.
Install at least one smoke detector on each oor of your
home to ensure your safety.
Install a conveniently located Class A re extinguisher
near the replace.
Devise a practiced evacuation plan, consisting of at least
two escape routes.
Devise a plan to deal with a chimney re:
- Evacuate.
- Notify the re department.
3
Important Safety and Operating Information
WARNING! Risk of Fire! Hearth & Home Technologies
disclaims any responsibility for, and the warranty and
agencylistingwillbevoidedbythefollowingactions.
DO NOT:
• operatedamagedreplace
• modifyreplace
• overre
• installanycomponentnotapprovedbyHearth&Home
Technologies
• installpartsorcomponentsnotListedorapproved
operate the fireplace without fully assembling all
components
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
1. Clear Space
Combustible materials must not be stored on the hearth
extension. Room furnishings such as drapes, curtains,
chairs or other combustibles must be at least 4 ft
(1219 mm) from the open front of the replace.
Combustible materials are materials made of or sur-
faced with any of the following materials:
- Wood - Compressed paper
- Plant bers - Plastic
- Plywood/OSB - Drywall
- Any material that can ignite and burn, ame proofed
or not, plastered or un-plastered.
WARNING! Risk of Fire! Keep combustible materials,
gasolineandotherammablevaporsandliquidsclearof
thereplace.
DO NOT:
• storeammablematerialsclosetothereplace
• use gasoline, lantern fuel, kerosene, charcoal lighter
uidorsimilarliquidstostartor“freshenup”areinthis
replace.
48 in. (1219 mm)
Clear Space
Front of Fireplace
12 in. (305 mm)
Clear Space
Sides of Fireplace
(from the FP opening)
48 1/8 in. (1222 mm)
Clear Space
Bottom of Fireplace to
Lower Edge of Mantel
or Trim
Figure 3.1 Clear Space
Non-combustible materials are materials which will not
ignite and burn, composed of any combination of the
following:
- Steel - Iron
- Brick - Tile
- Concrete - Slate
- Glass - Plasters
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
8
8. Chimney Fire
In the event of a chimney re
Have the chimney and adjacent structure inspected by
qualied professionals. Hearth & Home Technologies
recommends that NFI or CSIA certied professionals,
or technicians under the direction of certified
professionals, conduct a minimum of an NFPA 211
Level 2 inspection of the chimney.
Replace components of the chimney and replace
as specied by the professionals.
Ensure all joints are properly engaged and the
chimney is properly secured.
WARNING! Risk of Fire! A chimney re can perma-
nently damage your chimney system. Failure to re-
placedamagedcomponentsandmakeproperrepairs
cancauseastructurere.
7. Over-Firing Your Fireplace
WARNING! Risk of Fire! Donotover-re.
Over-firing may ignite creosote or will damage the
replaceandchimney.
Symptoms of over-ring may include one or more of the
following:
chimney connector or replace glowing
roaring, rumbling noises
loud cracking or banging sounds
metal warping
chimney re
Topreventover-ringyourreplace.DONOT:
• useammableliquids
• overloadwithwood
• burntrashorlargeamountsofscraplumber
2. Grate
This replace is designed to be used with the supplied
grate or one approved by HHT.
WARNING! Risk of Fire! Use only the factory-sup-
pliedintegralgrate.
• Keepslogsinplace.
• Allowsproperaircirculationaroundthere.
3. Refractory
The refractory is supplied to contain heat and provide
an attractive interior.
It will break down over time and will need occasional
replacement. Small hairline cracks and discoloration
are normal and do not affect its safety.
WARNING! Risk of Fire! DO NOT burnreplacewith-
out refractory. Use only refractory supplied by Hearth &
HomeTechnologies.
4. Firescreen
The rescreen is provided to control sparks. Keep it
closed when the replace in in use.
WARNING! Risk of Fire or Burns!
• Screenwillnotpreventburningmaterialsfromfalling
out.
• Screenpullsorhandlesmaybehot.
5. Flue Damper
The ue damper must be in the fully opened position
during operation of the replace.
WARNING! Risk of Fire and Asphyxiation! Open
damperpriortooperatingreplace.Acloseddamper
overresthereplaceandspillssmokeandames
into the room.
6. Glass Doors
Glass doors are optional.
WARNING! Risk of Fire! InstallONLYdoorsapproved
byHearth&HomeTechnologies.
WARNING! Risk of Fire and Smoke! Fireplace
equipped with doors should be oeprated only with
doors fully open or doors fully closed. If doors are left
partlyopen, gas and ame maybe drawnout ofthe
freplaceopening.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
9
close
Damper
Handle
Handle up - open
Handle down -
closed
Outside Air
open
B. General Operating Parts
WARNING! DO NOT operatereplacebeforereadingandunderstandingoperatinginstructions.Failuretooperatere-
placeaccordingtooperatinginstructionscouldcausereorinjury.
WARNING
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as replace.
Alert children and adults to hazards of high temperatures.
Hightemperaturesmayigniteclothingorotherammablematerials.
Keep clothing, furniture, draperies and other ammable materials away.
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down.
Figure 3.2 General Operating Parts
CAUTION! Ifyouexpectthatchildrenmaycomeintocontactwiththisreplace,werecommendabarriersuchasadecorative
screen.Seeyourdealerforsuggestions.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
10
3. Glass Doors
Glass doors are optional.
Refer to Figure 3.3 for how to properly use them.
1. Flue Damper
The ue damper must be in the fully opened position
(handle up toward the top of the repalce) during op-
eration of the replace.
Before lighting the replace, verify fully open position
by looking up from the inside of the replace.
FULLY OPEN
CORRECT
PARTLY CLOSED
INCORRECT
PARTLY OPEN
INCORRECT
FULLY CLOSED
CORRECT
Figure 3.3 Operating Positions of Bi-fold Doors
Refer to Figure 3.2 for location and operation of control.
The outside air kit supplies some combustion air for
your replace. It may help reduce the effects of nega-
tive air pressure.
Close the inlet to prevent cold drafts when the replace
is not being used
2. Outside Air
CAUTION! Outside air control handle may be warm.
Adjustbeforelightingre.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
11
WARNING! Risk of Fire!
• DO NOTburnwetorgreenwood.
• Wet, unseasoned wood can cause accumulation of
creosote.
Soft woods Hard woods
Douglas Fir Oak
Pine Maple
Spruce Apple
Cedar Birch
Poplar
Aspen
Alder
C. Fuel
1. Hardwood vs. Softwood
Your replace’s performance depends on the quality of
the rewood you use. One species of wood varies very
little to the other in terms of energy content. All sea-
soned wood contains about 8,000 BTU’s per pound.
Hardwoods have a greater density than softwoods; a
piece of hardwood will contain about 60% more BTU’s
than an equal size piece of softwood. A cord of sea-
soned oak (hardwood) would contain about 60% more
potential energy than a cord of seasoned pine (soft-
wood).
Most softwoods are coniferous. These are trees with
needle-like leaves that stay green all year and carry
their seeds exposed in a cone. Examples of conifer-
ous trees are Douglas r, pine, spruce and cedar. Soft-
woods, being more porous, require less time to dry,
burn faster and are easier to ignite than hardwoods.
Hardwoods are deciduous trees, broadleaf trees that
lose their leaves in the fall. Their seeds are usually
found within a protective pod or enclosure. Some ex-
amples of deciduous trees are oak, maple, apple, and
birch. However, it should be noted that there are some
deciduous trees that are denitely not considered hard-
woods such as poplar, aspen and alder. Hardwoods
require more time to season, burn slower and are usu-
ally harder to ignite than softwoods. Obviously, you will
use the type of wood that is most readily available in
your area. However, if at all possible the best arrange-
ment is to have a mix of softwood and hardwood. This
way you can use the softwood for starting the re, giv-
ing off quick heat to bring the replace up to operating
temperature. Add the hardwood for slow, even heat and
longer burn time.
2. Moisture content
The majority of the problems replace owners expe-
rience are caused by trying to burn wet, unseasoned
wood. Freshly cut wood can be as much water as it is
wood, having a moisture content of around 50%. Imag-
ine a wooden bucket that weighs about 8 pounds. Fill it
with a gallon of water, put it in the rebox and try to burn
it. This sounds ridiculous but that is exactly what you
are doing if you burn unseasoned wood. Dead wood
lying on the forest oor should be considered wet, and
requires full seasoning time. Standing dead wood can
be considered to be about two-thirds seasoned, if cut at
the dry time of the year.
Burning wet, unseasoned wood will produce less heat
output because it requires energy in the form of heat
to evaporate the water trapped inside. This is wasted
energy that should be used for heating your home. This
moisture evaporates in the form of steam which has
a cooling effect in your rebox and chimney system.
When combined with tar and other organic vapors from
burning wood it will form creosote which condenses in
the relatively cool rebox and chimney.
Even dry wood contains at least 15% moisture by
weight, and should be burned hot enough to keep the
chimney hot for as long as it takes to dry the wood out
- about one hour. To tell if wood is dry enough to burn,
check the ends of the logs. If there are cracks radiating
in all directions from the center, it is dry. If your wood
sizzles in the re, even though the surface is dry, it may
not be fully cured.
WARNING! For use with solid wood fuel only.
Otherfuelsmayoverreandgeneratepoisonousgases(i.e.
carbonmonoxide).
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
12
7. Processed Solid Fuel Firelogs
Manufactured relogs may be used with this replace.
Hearth & Home Technologies recommends the use of
UL Classied processed fuel relogs. Follow the manu-
facturer’s lighting and safety instructions.
Using relogs may require more frequent chimney in-
spections and cleaning.
Do not poke or stir the logs while they are burning. Use
only relogs that have been evaluated for the appli-
cation in manufactured replaces and refer to relog
warnings and caution markings on packaging prior to
use.
5. Burning Process
Fire requires fuel, air and heat. If heat is robbed from
the replace during the drying stage, the new load of
wood has reduced the chances for a good clean burn.
Aways burn dry, seasoned rewood.
6. Creosote Formation
When wood is burned slowly, it produces tar and other
organic vapors which combine with expelled moisture
to form creosote. The creosote vapors condense in
the relatively cool chimney ue of a newly-started or
a slow-burning re. As a result, creosote residue ac-
cumulates on the ue lining.
When ignited, creosote creates an extremely hot re
which may damage the chimney or even destroy the
house.
The chimney shall be inspected at least annually be-
fore lighting, or once every two months during heating
season.
When creosote has accumulated it shall be removed to
reduce the risk of a chimney re.
3. Seasoning
Seasoned rewood is nothing more than wood that is
cut to size, split and air dried to a moisture content of
around 20%. The time it takes to season wood varies
from around nine months for soft woods to as long as
eighteen months for hardwoods. The key to seasoning
wood is to be sure it has been split, exposing the wet
interior and increasing the surface area of each piece.
A tree that was cut down a year ago and not split is
likely to have almost as high a moisture content now as
it did when it was cut.
To season wood:
Cut logs to size
Split to 6 in. (152 mm) or less
Air dry to a moisture content of around 20%
- Soft wood - about nine months
- Hard wood - about eighteen months
NOTICE: Seasoningtimemayvarydependingondrying
conditions.
4. Storing Wood
Splitting wood before it is stored reduces drying time.
The following guideline will ensure properly seasoned
wood:
Stack the wood to allow air to circulate freely around
and through the woodpile.
Elevate the woodpile off the ground to allow air
circulation underneath.
The smaller the pieces, the faster the drying process.
Any piece over 6 in. (152 mm) in diameter should be
split.
Wood should be stacked so that both ends of each
piece are exposed to air, since more drying occurs
through the cut ends than the sides. This is true even
with wood that has been split.
Store wood under cover, such as in a shed, or covered
with a tarp, plastic, tar paper, sheets of scrap plywood,
etc., as uncovered wood can absorb water from rain
or snow, delaying the seasoning process. Avoid
covering the sides and ends completely. Doing so
may trap moisture from the ground and impede air
circulation.
D. First Fire
Before lighting your rst re in the replace, make certain
that:
refractory is in place
all labels have been removed
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
13
WARNING! Risk of Fire! Keep combustible materials,
gasolineandotherammablevaporsandliquidsclearof
thereplace.
DO NOT:
• storeammablematerialsclosetothereplace
• use gasoline, lantern fuel, kerosene, charcoal lighter
uidorsimilarliquidstostartor“freshenup”areinthis
replace.
E. Lighting Instructions
NOTICE: You must establish a good draft to prevent
smokespillageintotheroom.
The rst three or four res should be of moderate size to
allow the oils and binders to be burned from the replace
and the refractory and paint to cure. You may notice an in-
dustrial odor the rst few res. This is considered normal.
Use well-seasoned wood.
Open the ue damper to a fully open position.
Place crumpled or twisted paper under the replace
grate.
Loosely arrange kindling or small pieces of wood to form
a ‘tent’ on the replace grate.
Pre-warm the ue to establish a draft to help reduce
smoke spillage during start-up. Hold a rolled up piece
of burning newspaper under the ue damper for a few
moments.
Light the crumpled paper to ignite the kindling.
Add small pieces of wood until a hot bed of embers has
been established.
Add a minimum of three average size pieces of split
rewood, placed to allow combustion air and ames
between them.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
14
4
Maintenance and Service
WARNING! Hot Surfaces!
GlassandothersurfacesarehotduringoperationANDcool
down. DO NOTcleanreplaceuntilitiscooled.
Installation and repair should be done by a qualied
service technician only. The replace should be inspected
before use and at least annually by a professional service
person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please contact your dealer for a ser-
vice appointment.
A. Chimney Inspection
Frequency: As necessary; at least annually before
lighting replace, or once every two months during
heating season.
By: Homeowner/Chimney Sweep
Confirm that termination cap remains clear and
unobstructed.
Inspect for blockages such as bird nests, leaves, etc.
Inspect for corrosion or separation.
Inspect for creosote and remove as needed, at least
every two months during the heating season.
Inspect the system at the replace connection and
at the chimney top.
In the event of a chimney re, Hearth & Home Tech-
nologies recommends replacement of the chimney and
inspection of the adjacent structure to the provisions of
NFPA Level III inspection criteria.
WARNING! Risk of Asphyxiation and Fire! Annual
inspectionbyqualiedtechnicianrecommended.
Check:
• conditionofdoors,surroundsandfronts
• conditionofglassandglassassembly
• obstructionsofcombustionandventilationair
• obstructionsofterminationcap
Clean:
• glass
• airpassageways,grilles
WARNING! Risk of Fire! Ignitedcreosoteisextremely
HOT. Prevent creosote buildup.
B. Creosote (Chimney) Cleaning
Frequency: As needed; at least annually before light-
ing, or once every two months during heating season.
When creosote has accumulated it shall be removed
to reduce the risk of a chimney re.
By: Chimney Sweep
Tools Needed: Brush, Phillips screwdriver
When wood is burned slowly, it produces tar and
other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors
condense in the relatively cool chimney ue of a
slow-burnign fire. As a result, creosote residue
accumulates on the ue lining. When ignited, this
creosote makes an extremely hot re.
Remove all ash from the rebox and extinguish all
hot embers before disposal. Allow the replace to
cool completely.
Remove the top of the termination cap as shown in
Figure 4.1 to clean the cap and chimney.
The creosote or soot should be removed from the
chimney with a brush specically designed for the
size of chimney in use.
Reinstall termination cap.
Clean out fallen debris from the rebox.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
15
Figure 4.1 Chimney & Termination Cap Cleaning
C. Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
Warping or sagging 1-1/2 in. (38 mm) or more
Broken welds
Burn-through of grate bars
For safe operation, replace only with the approved grate
from Hearth & Home Technologies
E. Ash Removal
Frequency: As necessary
By: Homeowner
Tools Needed: Covered metal container, metal
shovel, replace broom
WARNING! Risk of Fire! DO NOT remove ashes until
thereisoutandthereplaceiscold.
Ashes should be placed in metal container with tight
tting lid.
The closed container of ashes should be placed
on a noncombustible oor or on the ground, well
away from all combustible materials, pending nal
disposal.
If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be retained
in the closed container until all cinders have
thoroughly cooled.
D. Glass Cleaning
Frequency: As necessary
By: Homeowner
Tools Needed: Vinegar or glass cleaner, soft towel
Clean glass with a non-abrasive glass cleaner. Use a
damp cloth dipped in wood ashes or a commercially
available oven cleaner. Remove any oven cleaner
residue with a glass cleaner or soap and water.
F. Refractory
Frequency: After each ash removal
By: Homeowner
Inspect condition of refractory. Replace if crumbly or
otherwise deteriorated, metal is exposed behind the
refractory, or if cracks exceed 1/4 in. (6 mm).
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
Chimney
Remove 4 screws
and lift top pan off.
Cap
Slip
Section
ST1175
ST475
Square Termination Cap
Cap
Remove screws,
lift top cover.
Top Cover
TR11/TR11T
TR444/TR442
Round Termination Cap
TCT1175
Terra Cotta
Termination Cap
Available US only
Remove 2 screws from
the front and back and
lift the top off.
1. REMOVE (8) SCREWS
2. LIFT TOP
TOP
TOP
SCREW
SCREW
DT SERIES
background
16
5
Troubleshooting
Start Fire Problems Possible Cause Solution
Can’t get re started
Excessive smoke or spillage
Burns too slowly
Smolders, sizzles
Not enough kindling/paper or no
kindling/paper
Use dry kindling, more paper. Arrange kindling & wood for
air movement.
Damper closed/not fully open Open damper.
Not enough air for re to ignite Check for restricted cap/shroud.
Open air kit (if installed).
Check for ue blockage.
Pre-warm ue before starting re (refer to starting re
section).
Check for adequate vent height (refer to chimney
assembly section).
Open window below the replace towards the wind.
Wood condition is too wet, too large Use dry, seasoned wood (refer to wood fuel section).
Bed of coals not established before
adding wood
Start with paper & kindling to establish bed of coals (refer
to starting re section).
Flue blockage such as birds’ nests
or leaves in termination cap
Have chimney inspected for creosote and cleaned by a
certied chimney sweep.
Down draft or negative pressure
Competition with exhaust devices
Do not use exhaust fans during start-up (refer to negative
pressure section).
Open window below the replace towards the wind.
Fire burns too fast Extremely dry or soft wood Mix in hardwood.
Mix in less seasoned wood after re is established (refer
to wood fuel section).
No glass doors Add glass doors to slow down air ow.
Overdrafting Check for correct vent height; too much vertical height
creates overdrafting.
Check location of vent termination (refer to chimney
assembly section).
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
17
A. FAQs
If smoke spillage occurs from a replace opening when
the door is open, there is either a leakage in the ue, a
blockage in the ue, or some condition is affecting draft
Understanding and differentiating the conditions which
can cause each of these kinds of spillage problems is
essential to their solution.
Flue Leakage
Check for improperly connected flue joints or a
damaged ue joint in the chimney system. Such
leakage would reduce draft (air would be drawn in
through the leaks rather than through the replace).
The result might be difficult start-up and smoky
res that might spill if other adverse draft conditions
accompany this problem.
Flue Blockage
The damper should be open.
Check for objects that may have fallen down the
chimney.
Be sure you have air available for combustion and that
your rewood is dry and well seasoned. Build your res
properly and according to the instructions given in op-
erating instructions, “Starting a Fire”. Be sure your ue
system is installed correctly and that it is the proper di-
ameter and height. Check for the following:
All chimney sections are properly installed.
The chimney is clean and free of creosote or soot
buildup.
Make sure overhanging trees and branches are cut
back within ten feet of the top of the chimney and the
chimney is free of debris from animals.
Ensure the chimney cap is clean and free of any
buildup of soot or creosote if cap is equipped with a
spark arrestor screen.
The wood being used in dry and well seasoned.
If you still suspect you have a low draft problem it may
be necessary to increase the volume of air in your
ue system. Since the diameter of your ue system is
matched with the size of the ue collar and should not
be changed, then the height of the system must be in-
creased. Add chimney sections one at a time until the
draft improves.
In some cases, regardless of what you do, it can still be
difcult to establish the proper ue draft. This is espe-
cially evident when using an exterior factory-built chim-
ney or exterior masonry chimney. Try holding a burning
rolled up newspaper as close to the ue outlet as pos-
sible for a few minutes, then light the paper under the
kindling. The heat generated from the burning rolled up
newspaper should help get the draft established.
Still other factors can affect how well your ue system
performs. Neighboring structures, high winds, tall trees,
even hillsides can affect air currents around the chim-
ney. Well designed chimney caps are available that can
help. Your replace dealer is the local expert in your
area. He can usually make suggestions or discover
problems that can be easily corrected allowing your
replace to operate correctly as it has been designed,
providing safe and economical heat for your home.
Flue draft is measured as negative pressure in the
chimney. The amount of negative pressure determines
how strong the draft is. The draft is important because
it draws the combustion air into the replace and pulls
the smoke out of the chimney.
There are three basic criteria essential in establishing
and maintaining ue draft:
availability of combustion air
heat generated from the re
diameter and height of the ue system
These three factors work together as a system to create
the ue draft. Increasing or decreasing any one of them
will affect the other two and thus change the amount of
draft in the entire system.
If the re is hard to start and smoke spills out of the re-
place, or you nd it difcult to establish and maintain a
moderately high burn rate, then the ue draft is too low
and corrective measures must be taken.
Hearth & Home Technologies assumes no responsibil-
ity for the improper performance of the replace sys-
tem caused by inadequate draft due to environmental
conditions, down drafts, tight sealing construction of
the structure, or mechanical exhausting devices which
will create a negative air pressure within the structure
where the replace is located.
Contact your dealer for additional informa-
tion regarding operation and troubleshoot-
ing. Visit www.majesticproducts.com to
ndadealer.
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
18
Another appliance in
home also exhausting
air (furnace, fan,
dryer, etc.)?
Air register from
furnace near
fireplace?
Doors opening
and closing?
Window closed
for start-up?
Outside air
closed?
Overhead fan
operating?
Overhanging
tree?
Bird's nest
or leaves in
termination
cap?
Structural
changes in
chimney area?
Creosote buildup
in flue?
S
t
r
o
n
g
w
i
n
d
s
a
r
o
u
n
d
c
h
i
m
n
e
y
t
e
r
m
i
n
a
t
i
o
n
?
Unsealed
can lights?
Combustion
air control
Figure 5.1 Factory-built Fireplaces: Troubleshooting
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
19
6
Reference Materials
A. Service Parts
Service Parts
BILTMORE (SB60, SB60HB)
Beginning Manufacturing Date: N/A
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does
not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER
1 Starter Section Assembly 22072B
2 Damper Blade Assembly 29964
3 Damper Control 20549
Damper Weight 19785
4 Rear Top Standoff Qty 2 req 19228
5 Front Top Standoff Qty 2 req 11864
6 Top Front SRV4013-206BK
7 Top Front Face SRV31313BK
8 Column (Right or Left) SRV4013-004BK
9 Bottom Front Face SRV31311BK
10 Grate GR30
11 Smoke Shield SRV32949BK
12 Firescreen Assembly Qty 2 req 33699
Firescreen Handle 1 ea. 10002
Firescreen Rod Qty 2 req 12052
Grate Retainer Qty 2 req 4017-060
Nailing Flange Qty 4 req 31190
Outside Air Kit AK22
Fastener Pack 13580
Outside Air Shield 33271
4 in. Outside Air Inlet Ring 25692
Screen Cover (top only) SRV31319BK
Side Trim Qty 2 req SRV31326BK
Strip Protector Qty 2 req 18320
Touch-Up Paint 71479
Additional service parts on following page.
4/16
36“ Woodburning Fireplace
4
5
6
7
8
9
10
11
12
1
2
3
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
20
Service Parts
BILTMORE (SB60, SB60HB)
Beginning Manufacturing Date: N/A
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does
not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER
Herringbone Refractory (SB60HB)
Brick Refractory - Back SRV4013-337
Brick Refractory - Hearth SRV4013-321
Brick Refractory - Left Side SRV4013-339
Brick Refractory - Right Side SRV4013-338
Traditional Refractory (SB60)
Brick Refractory - Back SRV4013-322
Brick Refractory - Hearth SRV4013-321
Brick Refractory - Side SRV4013-323
Refractory Retainer
Qty 3 req
11847
Owner’s Manual 4013-301
Installation Manual 4013-300
Traditional
Herringbone
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
21
Service Parts
BILTMORE (SB80, SB80HB)
Beginning Manufacturing Date: N/A
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does
not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER
1 Starter Section Assembly 22072B
2 11” Damper Blade Assembly 29964
3 Damper Control 20549
Damper Weight 19785A
4 Rear Top Standoff Qty 2 req 19228
5 Front Top Standoff Qty 2 req 11864
6 Top Face SRV4013-207BK
7 Top Front Face SRV29922BK
8 Column (Right or Left) SRV4013-004BK
9 Bottom Front Face SRV4013-003BK
10 Grate GR29
11 Smoke Shield SRV29946BK
12 Firescreen Assembly Qty 2 req 29958
Firescreen Handle 1 ea. 10002
Firescreen Rod Qty 2 req 28404
Grate Retainer Qty 2 req 4017-060
Nailing Flange Qty 4 req 31190
Outside Air Kit AK22
Fastener Pack 13580
Outside Air Shield 33271
4 in. Outside Air Inlet Ring 25692
Screen Cover (top only) SRV29926BK
Side Trim Qty 2 req SRV31326BK
Strip Protector Qty 2 req 18320
Touch-Up Paint 71479
Additional service parts on following page.
4/16
42” Woodburning Fireplace
1
2
3
9
4
5
6
7
8
10
11
12
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
22
Service Parts
BILTMORE (SB80, SB80HB)
Beginning Manufacturing Date: N/A
Ending Manufacturing Date: Active
Traditional
Herringbone
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does
not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM DESCRIPTION COMMENTS PART NUMBER
Herringbone Refractory (SB80HB)
Brick Refractory - Back SRV4013-342
Brick Refractory - Hearth SRV4013-326
Brick Refractory - Left Side SRV4013-339
Brick Refractory - RightSide SRV4013-338
Traditional Refractory (SB80)
Brick Refractory - Back SRV4013-327
Brick Refractory - Hearth SRV4013-326
Brick Refractory - Right/Left Side SRV4013-323
Refractory Retainer Qty 3 req 11847
Owner’s Manual 4013-301
Installation Manual 4013-300
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
23
B. Accessories
SB60 SB80 Description
DM6036 DM8042 Glass doors - Bi-fold, clear view, black
DM6036S DM8042S Glass doors - Bi-fold, clear view, stainless steel
HX4 HX4 Hearth extension
Bi-fold Glass Doors
Gas Inserts
Gas Log Sets
Gas Log Lighters
Wood-burning Inserts
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
background
24
Majestic Biltmore Series • SB60/SB80 Owner’s Manual • 4013-301 • Rev B • 03/17/16
C. Contact Information
– NOTES –
Printed in U.S.A. - Copyright 2012
DO NOT DISCARD THIS MANUAL
CAUTION
Leave this manual with
party responsible for use
and operation.
Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
This
product may be covered by one or more of the following patents: (United States) 5000162, 5016609, 5076254, 5113843,
5191877,
5218953, 5263471, 5328356, 5341794, 5347983, 5413089, 5429495, 5452708, 5542407, 5890485, 5931661, 5941237,
5947
112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226,
6484712,
6543698, 6550687, 6601579, 6672860, 6688302, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942,
6769426,
6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,7047962,
7216645, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or
other U.S. and foreign patents pending.
Please contact your HHT dealer with any questions or concerns.
Majestic, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.majesticproducts.com

Specifications

Indexed Terms: Wood-Burning

Majestic SB80 Questions and Answers

See other models: SB80HB DSR36 SSTB11 MONTANA36 DSR42