Blaze BLZ3PRONG 34" BuiltIn Professional Grill

User Manual - Page 16

For BLZ3PRONG. Also, The document are for others Blaze models: BLZ-2PRONG, BLZ-2PROLP, BLZ-3PRONG, BLZ-3PROLP, BLZ-4PRONG, BLZ-4PROLP

PDF File Manual, 40 pages, Read Online | Download pdf file

BLZ3PRONG photo
Loading ...
Loading ...
Loading ...
Blaze Outdoor Products Instructional Book
Page | 16
cylinder with right handed connection threads and this is the maximum size LP tank to be used. The
cylinder must be
marked in accordance with the latest U.S. Department of Transportation specifications for LP
gas cylinders. (DOT. CFR49 or
National Standards of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for
the Transportation of Dangerous Goods) a
Propane Tank with an ODP) Overfill Prevention Device) must be used
at all times.
IMPORTANT: Never connect the appliance to an unregulated gas supply.
If there are local codes that apply to the outdoor grills, you will have to confirm them with the local authority..
The installation of this appliance must conform with local codes or in the absence of local codes, to the national
fuel gas code,
ANSI Z223.1a-1998. Installation in Canada must be in accordance with the standard CAN/CGA-
B149.2, Propane Installation
Code.
A licensed contractor or local gas company representative must perform all natural gas connections.
Ensure that the service supplying the appliance is fitted with a shut off valve conveniently positioned near the
appliance
and giving ease of access.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any
pressure testing of the gas supply piping system at test pressures equal to or less than 0.5 psi (3.5
kPa).
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure
testing of that system at test pressure in excess of 0.5 psi (3.5 kPa).
GAS LEAK WARNINGS
Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure ONLY USE A PROFESSIONAL.
NEVER USE THE GRIDDLE WITHOUT FIRST LEAK TESTING THE GAS CONNECTIONS INCLUDING ALL
OF THE VALVES, FITTINGS, LINES ETC. (ALL GAS CONNECTIONS SHOULD BE CHECKED)
WARNING: DO NOT USE OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN FLAME
COULD RESULT IN A FIRE, EXPLOSION AND BODILY HARM.
DO NOT SMOKE WHILE PERFORMING THE LEAK TEST. Any open flame will ignite the gas.
To prevent fire or explosion hazard, Perform leak test outdoors only.
Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety before each use.
Only the factory supplied hose and regulator must be used. Use only replacement regulator and hose assemblies
specified by BLAZE OUTDOOR PRODUCTS.