C.
Turn On Your KwiKool System - Pressing the ON/OFF button once on your control
panel will put your unit in the ON position and “ON” will be displayed on the right
side of your display as well as the previously chosen mode.
COOL - If the unit was previously set to the cooling mode (cool) then “cool” will be
displayed. If the compressor is running, the ”cool” on the display will be flashing. If
your unit has been sitting for over 2 minutes, this should happen immediately upon
turning the unit on, unless your set point is lower than the current room tempera-
ture. In this case your unit is ready to automatically turn on once the temperature
rises above the set point. If the unit was recently turned off or the unit turned itself
off because it reached the set point, the compressor will not turn on until the
system waits for approximately 2 minutes. This prevents the compressor from
being damaged do to a condition called short cycling. The indicator that the unit is in
the “time out” condition is that the F (or C) in the display will be flashing. When the
compressor starts, the F will stop flashing and the “COOL” will begin flashing.
**Note: the condenser water supply will not start to flow immediately but is
controlled by head pressure. If the display flashes 99, this indicates the ambient
temperature is 99 degrees F or higher. This is normal and will stop flashing when
the ambient temperature falls below 99 degrees F.
FAN - If the unit was previously set to the fan mode then “FAN” will be displayed
and the fan will start to run.
System Operation -
1.
Page 8
a.
b.
Lowering or raising the set point will not change the temperature of the
supply air. For best results always adjust the set point to a temperature your
KwiKool can cycle on and off at to avoid operational issues such as freezing or
rapid discharge fan cycling, KwiKool systems are designed to maintain the set
point when sized properly and constant operation without achieving the set
point may shorten the expected operational life of your system.
The lowest set point temperature available for your KwiKool is 60 degrees F,
and the highest setting is 95 degrees F. The control will not allow adjustments
beyond these ranges.
NOTES:
V / Built in Safeguards
KwiKool is proud to provide its customers with high quality features and safety devices
that are not found in most other brands.
2.
3.
Time Delay - Protects your KwiKool from potential damage by delaying the compres-
sor from starting before the pressures in the mechanical system equalize. This always
activates when your KwiKool cycles off, is turned off, power is lost and then restored or
the operational mode is changed. Display flashes C or F if the time delay is activated.
Condenser Water Control Valve - Part of your KwiKool limited freeze protection
and works by regulating the discharge water flow to keep the refrigerant pressures at
the optimum range.