WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
-7-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
Connect the power cord to a 3-prong, grounded extension cord adequately rated for this applicaon.
Extension Cord Wire Requirements:
• 6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.
• 11 to 100 feet (3.4 to 30.5 meters) long, use 16 AWG conductor.
• 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.
Supply Valve
Propane Tank
Regulator
Hose
Hose
Inlet
Connector
OPERATING INSTRUCTIONS
UNPACKING
1. Remove the heater from the carton.
2. Remove all packing materials applied to the heater for shipment.
3. Remove all items from the carton.
4. Check the heater for shipping damage. If heater is damaged, promptly inform PowerFast Products Group at (423) 837-5155.
INSPECTION AND PREPARATION
1. Check the heater for possible shipping damage. If there is visible damage or a missing part, immediately contact PowerFast
Products Group for assistance at (423) 837-5155.
2. Inspect the hose assembly prior to using the heater. If there is evidence there is excessive abrasion or wear, or the hose is cut,
replace the hose prior to operang the heater.
3. DO NOT CONNECT THE POWER CORD TO AN OUTLET UNTIL YOU HAVE FINISHED THE PREPARATION.
4. Connect the POL fing of hose and regulator assembly to the propane cylinder by rotang the POL nut counterclockwise
into the propane cylinder’s valve outlet and securely ghten with a wrench.
5. Connect the hose to the heater by rotang the hose fing clockwise.
6. Securely ghten all gas connecons with a wrench.
7. Open the cylinder’s gas valve and check all gas connecons with a soap and water soluon. DO NOT USE A FLAME. If
bubbles appear, there is a leak. Tighten all of the connecons and retest for leaks.
8. Unloosen the adjustment knob, set the heater to the desired height, and ghten the knob.
MODEL R45LP R60LP R125LP R160LP
Rang BTU/h 45k 40-50-60k 90-110-125k 120-135-155k
Fuel Consumpon 2.1 lb/h 1.8/2.3/2.8 lb/h 4.4/5.1/5.8 lb/h 5.5/6.2/7.2 lb/h
Electrical Input 120V/60Hz/0.5A 120V/60Hz/0.5A 120V/60Hz/1.03A 120V/60Hz/1.03A
Manifold Pressure 11” W.C. 11” W.C. 8.7” W.C. 6.2” W.C.
SPECIFICATIONS
MODEL HL45G HF60G HF125G HF160G
Rang BTU/h 45k 40-50-60k 90-110-125k 120-135-155k
Fuel Consumpon 2.1 lb/h 1.8/2.3/2.8 lb/h 4.4/5.1/5.8 lb/h 5.5/6.2/7.2 lb/h
Electrical Input 120V/60Hz/0.5A 120V/60Hz/0.5A 120V/60Hz/1.03A 120V/60Hz/1.03A
Manifold Pressure 11” W.C. 11” W.C. 8.7” W.C. 6.2” W.C.