www.factorybuysdirect.com
21200415-01A
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Approx. 3"-6" Above Top of Logs
More Than 8" Above Top of Logs
Figure 22 - Correct Pilot Flame Pattern
(Natural Gas shown)
Figure 23 - Incorrect Pilot Flame Pattern
(Natural Gas shown)
Figure 24 - Correct Burner Flame Pattern
with Control Knob Set to HI (5)
Figure 25 - Incorrect Burner Flame
Pattern with Control Knob Set to HI (5)
INSPECTING BURNERS
BURNER FLAME PATTERN
Figure 24 shows a correct burner ame pattern. Figure 25 shows an incorrect burner ame
pattern. If burner ame pattern is incorrect then:
turn heater off (see To Turn Off Gas to Appliance, page 20).
see Troubleshooting pages 24 through 27.
BURNER PRIMARY AIR HOLES
Air is drawn into the burner through the holes in the tting at the entrance to the burner. These
holes may become blocked with dust or lint. Periodically inspect these holes for any blockage
and clean as necessary. Blocked air holes will create soot.
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
NG
3-3.5" WC
Natural Gas
Shown
LP
8-11" WC
(Logs will vary from those shown)