Loading ...
Loading ...
Loading ...
37MAINTENANCE
ENGLISH
CAUTION
To reduce the risk associated with property
damage due to water leakage:
Read and follow Use Instructions before
installation and use of this system.
Installation and use MUST comply with
all state and local plumbing codes.
Do not install if water pressure exceeds
120 psi (827 kPa). If your water pressure
exceeds 80 psi (552 kPa), you must install
a pressure limiting valve. Contact a plumb-
ing professional if you are uncertain how to
check your water pressure.
Do not install where water hammer
conditions may occur. If water hammer
conditions exist you must install a water
hammer arrester. Contact a plumbing
professional if you are uncertain how to
check for this condition.
Do not install on hot water supply lines.
The maximum operating water tem-
perature of this filter system is 100°F
(37.8°C).
Protect filter from freezing. Drain filter
when temperatures drop below 40°F
(4.4°C).
The disposable filter cartridge MUST be
replaced every 6 months, at the rated
capacity or if a noticeable reduction in
flow rate occurs.
Protect from freezing, remove filter car-
tridge when temperatures are expected
to drop below 33° F (0.6 ºC).
Do not install systems in areas where
ambient temperatures may go above
110° F (43.3° C). Where a backflow
prevention device is installed on a water
system, a device for controlling pres-
sure due to thermal expansion must be
installed.
Ensure all tubing and fittings are secure
and free of leaks.
NOTE
While the testing was performed under
standard laboratory conditions, actual
performance may vary.
WARNING
To reduce the risk associated with chok-
ing:
Do not allow children under 3 years of
age to have access to small parts dur-
ing the installation of this product.
To reduce the risk associated with the
ingestion of contaminants:
Do not use with water that is microbi-
ologically unsafe or of unknown quality
without adequate disinfection before or
after the system. Systems certified for
cyst reduction may be used on disin-
fected water that may contain filterable
cysts. EPA Establishment # 070595-
MEX-001
Replacement Cartridge: ADQ73613401
It is essential that the manufacturers recom-
mended installation, maintenance and lter
replacement requirements be carried out for the
product to perform as advertised.
Service Flow
Water Supply
Water Pressure
Water Temperature
0.5 gpm (1.9 lpm)
- Potable Water
20 -120 psi (138 - 827 kPa)
33°F - 100°F (0.6°C - 38°C)
Application Guidelines/
Water Supply Parameters
Manufactured for LG Electronics by MCM Co.,
Ltd. 45-10, Nowon-Ri, Yiwol-Myun, Jinchun-Kun,
Chung-Buk, Korea.
For estimated costs of replacement elements
please call 01 8000 910 683 (24 hours per
day/7 days per week) or visit our website at
www.lge.com
Loading ...
Loading ...
Loading ...