Thermador PALPKITHW5 Accessories cookers/ovens

User Manual - Page 5

For PALPKITHW5.

PDF File Manual, 51 pages, Read Online | Download pdf file

PALPKITHW5 photo
Loading ...
Loading ...
Loading ...
Page. 5
9 IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
The following must be met when testing supply piping
system:
The appliance and its individual shut-off valve
must be disconnected from the gas supply piping
system at test pressures in excess of 1/2 psig
(3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/ 2 psig (3.5 kPa).
CAUTION
When connecting the unit to propane gas, make
certain the propane gas tank is equipped with its own
high pressure regulator. The maximum gas pressure to
this appliance is not to exceed 14.0 inches water
column from the propane gas tank regulator.
State of California Proposition 65 Warning:
: WARNING
This product can expose you to chemicals including
vinyl chloride, which is known to the State of California
to cause cancer and birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
WARNING
NEVER leave the gas conversion partially completed.
If the appliance is operated while the gas conversion is
incomplete, high levels of carbon monoxide may be
emitted, or a fire or explosion may occur.
To the service agent
It is important that you know the following BEFORE you
begin the conversion of the appliance.
Confirm that the gas supply system is available and
ready to use. This is particularly important for new
construction.
Verify the type of gas supplied to the location. Ensure
that the appliance is connected to the type of gas for
which it is certified.
You must plan for sufficient time and resources to
perform the conversion process properly and
completely before leaving the job site. Every step
described in these instructions must be performed to
safely convert the appliance for proper operation with
propane (LP) gas. INCOMPLETE OR INADEQUATE
CONVERSION OF THE APPLIANCE CAN CREATE A
SAFETY HAZARD.
Gas and dual fuel ranges converted for propane (LP)
gas and high altitude
The appliance must first be converted for use with
propane (LP) gas before it can be converted for use at
high altitude. It is required that a qualified technician
install the high altitude kit.
Loading ...
Loading ...
Loading ...