Maintenance and Service
WARNING! Hot Surfaces!
GlassandothersurfacesarehotduringoperationANDcool
down. DO NOTcleanreplaceuntilitiscooled.
Installation and repair should be done by a qualied
service technician only. The replace should be inspected
before use and at least annually by a professional service
person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please contact your dealer for a ser-
vice appointment.
A. Chimney Inspection
Frequency: As necessary; at least annually before
lighting replace, or once every two months during
heating season.
By: Homeowner/Chimney Sweep
• Confirm that termination cap remains clear and
unobstructed.
• Inspect for blockages such as bird nests, leaves, etc.
• Inspect for corrosion or separation.
• Inspect for creosote and remove as needed, at least
every two months during the heating season.
• Inspect the system at the replace connection and
at the chimney top.
In the event of a chimney re, Vermont Castings Group
recommends replacement of the chimney and inspec-
tion of the adjacent structure to the provisions of NFPA
Level III inspection criteria.
WARNING! Risk of Asphyxiation and Fire! Annual
inspectionbyqualiedtechnicianrecommended.
Check:
• conditionofdoors,surroundsandfronts
• conditionofglassandglassassembly
• obstructionsofcombustionandventilationair
• obstructionsofterminationcap
Clean:
• glass
• airpassageways,grilles