To display the temperature readings in Fahrenheit (°F) or Celsius (°C), slide the switch on the back of the unit
to °F or °C.
Displaying °F or °C
Note: The unit must be reset after changing the temperature unit.
To select normal sampling rate (60 seconds) or fast sampling rate (10 seconds), slide the switch on back of unit
to NORMAL or FAST.
Selecting the Sampling Rate
Note: The unit must be reset after changing the sampling rate. Using the NORMAL sampling rate will
extend battery life.
SUMMIT alarms have two operating modes: NORMAL
DISPLAY MODE and ALARM DISPLAY MODE. To
change from one mode to another, press the MODE
button once.
Operation Modes
NORMAL DISPLAY MODE - is indicated by the display
of current temperature and the MIN (minimum) and MAX
(maximum) temperatures. These temperatures relate to
internal (probe) temperature if the probe is plugged in,
and to ambient temp if the sensor probe is removed.
ALARM DISPLAY MODE - is indicated by the display of
current temperature and the HI and LO alarm settings.
These temperatures relate to internal (probe) temperature
if the probe is plugged in, and to ambient temperature if
the sensor probe is removed.
There are two ways to reset the memories:
Resetting MIN/MAX Memories
1. To reset both minimum and maximum memories: Press the MEMORY CLEAR button.
2. To reset individual minimum and maximum memories: Press either the MIN or MAX button (on back of unit)
once to reset the respective memory. The other memory will remain unaffected.
Note: You must be in NORMAL Display Mode to reset the memories.
1. Press the MODE button until unit is in the ALARM DISPLAY MODE indicated by the display of current
temperature and HI/LO alarm settings.
Setting the HIGH/LOW Alarm
2. To set the HIGH temperature alarm limit, press the HI button to advance
the display in 1° increments, until
the desired high temperature is displayed.
Press and hold the HI button to advance the display rapidly in 5°
increments.
3. To set the LOW temperature alarm limit, press the LO button to advance
the display in 1° increments, until
the desired low temperature is displayed. Press and hold the LO button to advance the display rapidly in 5°
increments.
The unit will sound the alarm in both NORMAL DISPLAY MODE and ALARM DISPLAY MODE. Slide the
ALARM ON/OFF switch to ON. When the current temperature display rises above the HI set point, or falls
below the LO set point, the alarm will sound for 1 minute and issue a 3-second repeater beep every minute
thereafter for up to 12 hours. The alarm will continue to sound even if the current temperature display returns to
an “in range” condition.
Alarm
To temporarily silence the alarm, press either the HI or LO button on the back of the unit. The unit is still active
and the alarm will sound again if the temperature goes out of range.
To permanently silence the alarm, slide the ALARM ON/OFF switch to the OFF position.