Legrand WWP30CCV2 radiant Smart WiFi Plug-In 3-Outlet Outdoor GFCI

User Manual - Page 7

For WWP30CCV2.

PDF File Manual, 12 pages, Read Online | Download pdf file

WWP30CCV2 photo
Loading ...
Loading ...
Loading ...
warnings
If the GFCI fails to trip when the Test button is pressed (lamp indicator fails to
turn white) or, if the GFCI fails to reset when the Reset button is pressed (lamp
indicator fails to remain green), the device should be replaced.
If the GFCI tests properly without any appliance plugged into it, but trips each
time the appliance is plugged in, the appliance has a ground fault and needs
to be repaired or replaced. DO NOT BYPASS THE GFCI. IF THIS CONDITION
OCCURS, A REAL SHOCK HAZARD MAY EXIST.
cautions
1. Do not connect any electrical cord longer than 250 feet to the GFCI output
receptacle in order to avoid possibility of nuisance tripping.
2. This GFCI device is to be used on 120V/60Hz circuit only (such as normal
house-hold electrical distribution system).
3. Ground fault circuit interrupters, whether this device or any other, cannot
protect against electrical shock resulting from contact with both hot and
neutral wires of the electrical circuit nor against defects in any wiring
supplying the device.
4. DO NOT USE IF THE BUTTON BOOTS OR CASE OR CORD HAVE
BEEN DAMAGED.
5. Test frequently and at least before each use of load equipment to ensure
correct operation.
6. The GFCI is designed as a protective device.
7. Do not use on circuit with life support apparatus.
Loading ...
Loading ...