Marvel MP15CPG3RS Professional Series 15 Inch Stainless Steel Undercounter Ice Maker

User Manual - Page 34

For MP15CPG3RS.

PDF File Manual, 72 pages, Read Online | Download pdf file

MP15CPG3RS photo
Loading ...
Loading ...
Loading ...
34
DRAIN PUMP REMOVAL INSTRUCTIONS
Additional issues to be inspected by
the installer upon service replacement:
1. The drain pump must be level.
2. No pinched water lines.
3. No interference with electrical cords or wiring.
4. The drain pump should not set on any
obstacles, wiring, etc.
5. Secure all hose clamps leading to and from
the drain pump.
6. Insure that the vent tube height is adequate -
18 inches minimum.
7. Insure that drain height is adequate -
maximum of 8 feet.
8. Insure that drain length is adequate -
maximum of 20 feet.
9. Checked for water leaks after installation of
the drain pump.
10. Check for vibrations caused by improper
installation.
11. Insure that there is no interference with back
access cover.
12. Insure that the hole grommets are in place at
each location so that any vent or drain tubes
do not rub on any sharp surfaces.
Ice machine
power cord
Figure 56
Rotate drain pump and
remove from back of
ice machine.
Figure 55
6. Rotate the drain pump and remove from the ice
machine, (See Figure 55). It may be necessary to
disconnect the ground wire connection in the back
ange of the cabinet. (See Figure 51).
7. Disconnect the ice machine power cord from the drain
pump (See Figure 56).
8. Drain the water in the drain pump’s reservoir by turning
the pump upside down and allowing water to drain
through the pump’s inlet and vent tube ttings.
9. Installation of drain pump is reverse of this procedure.
Loading ...
Loading ...
Loading ...