Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/53326783-cpf92gma/bg2d.png)
Installation
101
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31 AUX SR R DUAL
Rated heating capacity (kW)
1.0 1.75 3.0 4.0
Nozzle diameter (1/100 mm)
50 65 85 100
Pre-chamber (printed on nozzle)
--- -
Reduced flow rate (W)
400 500 800 1300
Rated flow rate G30 (g/h)
73 127 218 291
Rated flow rate G31 (g/h)
71 125 214 286
8 LPG G30/31 AUX SR R DUAL
Rated heating capacity (kW)
1.1 1.9 3.0 4.2
Nozzle diameter (1/100 mm)
50 65 81 95
Pre-chamber (printed on nozzle)
--- -
Reduced flow rate (W)
450 550 900 1500
Rated flow rate G30 (g/h)
80 138 218 305
Rated flow rate G31 (g/h)
79 136 214 300
9 LPG G30/31 AUX SR R DUAL
Rated heating capacity (kW)
1.0 1.8 3.0 4.1
Nozzle diameter (1/100 mm)
43 58 74 80
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (F4)
Reduced flow rate (W)
400 500 1000 1500
Rated flow rate G30 (g/h)
73 131 218 298
Rated flow rate G31 (g/h)
71 129 214 293
10 Town gas G110 AUX SR R DUAL
Rated heating capacity (kW)
1.0 1.75 2.8 3.4
Nozzle diameter (1/100 mm)
145 185 260 340
Pre-chamber (printed on nozzle)
/8 /2 /3 0190
Reduced flow rate (W)
400 500 800 1200
Loading ...
Loading ...
Loading ...