KEY DiMENSiONS AND SPECiFiCATiONS
Description Dryer (Gas and Electric)
Electrical Requirements Refer to the rating labet
Gas Requirements _ NG: 4-10.5 inches WC (Water Column)
Gas Requirements _ LP: 8-13 inches WC
Dimensions 27 in. (W) X 30 1/4in. (D) X 38 in. (H), 52 1/4 in. (D with door open)
68.6 cm (W) X 76.7 cm (D) X 96.5 cm (H), 132.7 cm (D with door open)
Net Weight Electric : 147 lb. (66.7 kg) Gas : 150.5 lb. (68.3 kg)
Drying Capacity IEC 7.3 cu. ft.
_Gas Models Only
LOCATION REQUIREMENTS
Standard Installation - Side View
iMPORTANT: Read att installation instructions
completely before installing and operating your dryer, i
It is important that you review this entire manual before 2o 1/8in.
installing and using your dryer. It contains detailed
(56.2 cm)
instructions concerning electrical connections, gas
connections and exhaust requirements.
CHOOSE THE PROPER LOCATION
* Store and install the dryer where it witl not be exposed
to temperatures below freezing or exposed to outdoor
weather conditions.
* Choose a location with a solid, level floor.
*If the dryer is being installed in a garage, place the
dryer at least 18 inches (45.7cm) above the floor.
* Properly ground the dryer to conform with all
governing codes and ordinances.
* To reduce the risk of electric shock, do not install the
dryer in damp or wet locations.
iMPORTANT: If you are installing your dryer in a
manufactured or mobile home, please refer to the
Special Electrical Requirements for Mobile or
Manufactured Homes section.
CLEARANCES
* Most installations require a minimum 5 1/2 inch (14 cm)
clearance behind the dryer for the exhaust ducting.
* Allow minimum clearances of at least 1 inch (2.5 cm)
on the sides and back to minimize vibration and noise.
* Allowing additional clearance for installation and
servicing is recommended.
Be sure to allow for wall, door, or floor moldings that
may increase the required clearances.
* Allow at least 21 inches (53.3 cm) in front of the dryer
to open the door.
Standard Installation - Front View
oJo
in.
cm)
l in. l in.
(2.5 cm) 27 in. (2.5 cm)
(68.6 cm)
m
J
3"
(7.6 cm)
_ Vent
48 sq. in. --
(310 sq. cm.)
Vent
24 sq. in.
(155 sq. cm.)
y -
3" _
(7.6 cm)
0
Additional instructions for closet installations:
The closet door must allow for sufficient airflow. Refer to the
diagram above for minimum vent opening requirements. A
louvered door is also acceptable.