Airo 10 Outdoor Radiant Heater OIM
REGULATORY REQUIREMENTS
The heater must be installed in accordance with the manufacturers installation instructions.
The heater MUST ONLY be installed or removed by an authorised person.
The heater MUST be installed in accordance with AS/NZS 3000 and all other applicable local municipal
building codes including OH&S requirements
UNPACKING
IMPORTANT
If any damage is present DO NOT INSTALL or OPERATE the appliance and contact your supplier
for advice.
APPROXIMATE HEATING AREA
A
B
C
Heater
Indoor Area Spot Heating
Dimension AOD18 AOD24
A 1225 1505
B 2050 2650
C 2150 2150
Outdoor Covered / Enclosed Area
Dimension AOD18 AOD24
A 1225 1505
B 1600 2050
C 2150 2150
OUTDOOR RADIANT HEATER MOUNTING
This outdoor radiant heater comes with a pair of stainless steel adjustable angle mounting brackets. The adjustable
angle enables the heater to be installed on vertical, horizontal and inclined surfaces.
The ideal mounting position is directly above the area to be heated with a longitudinal orientation and facing
vertically downwards. If this is not possible, the heater(s) can be mounted on a wall and angled downwards. For
this application ensure the mounting height is within 2.1m to 2.7m.
WARNING
The heater must never be installed in the upwards or inwards facing position, the heating surface
must always be positioned to direct the heat in a downwards or outwards direction.
Vertical wall mount
Inclined ceiling mount
Horizontal ceiling mount
Angled horizontal ceiling mount
Correct Installation
Incorrect Installation
WALL
WALL
WALL
CEILINGCEILINGCEILING
WALL
CEILING