Amana AMC2165AB0 1.6 cubic foot countertop microwave

User Manual - Page 2

For AMC2165AB0.

PDF File Manual, 12 pages, Download pdf file

Loading ...
iNSTALLATiONiNSTRUCTiONS
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
[] Measuring tape [] Drill
[] Pencil [] 7/64" drill bit
[] Phillips screwdriver
Parts Supplied (not shown to scale
Rails (2)
Bottom duct Trimkit frame
tJ
Short screws (14)
(11+ 3 extra)
Long wood screws (6 - painted)
(4 + 2 extra)
LOCC] O_'_: ,,_ _, ............
The microwave oven may be installed over a built-in oven. if
installing over a built-in oven, make sure there is a minimum of 3"
(7.6 cm) between the top of the lower oven cutout and the
microwave oven cutout floor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36" (91.4 cm) from the floor to the cutout
floor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 1%_" (4.0 cm) below the
cutout floor (3" [7.6 cm] for installation above a built-in oven), and
a clearance of at least 2" (5.1 cm) above the cutout opening.
2 II
(5.1cm)
19/16"
II A
O O ...........i....................
T
36"
(91.4 c
JL 2"
cm)
3 II
"(7.6 cm)
A. Upper cabinet D. Lower cabinets
B. Microwave oven cutout E.Floor
C. Lower oven cutout
I
For minimum depth requirements, see chart.
t
17" (43.2em)
min.
17Va"(43.6era)
max.
11/'16"
(2.7 cm)
A
3 II
(7.6 cm)
D C
11/'16"
(2.7 cm)
B
A. Trim kit frame overhang
B. Cutout for lower oven
C. Recommended region for receptacle
location (no less than 6" [15.2 cm] to
the right of cutout centerline)
D. Cutout centerline
Receptacle Location Minimum Depth
Within recommended 18" (45.7 cm) with flush receptacle;
region 21" (53.2 cm) with non-flush receptacle
Outsiderecommended 19V2"(49.5 cm) with flush receptacle;
region 22V2" (57.2 cm) with non-flush
receptacle
NOTES:
[] Depth requirements depend upon receptacle and its location
within or outside of recommended region. See illustration and
chart above.
[] Height dimension is critical: 17" (43.2 cm) minimum, 17Vs"
(43.5 cm) maximum.
[] Width measurement has +1/16" (2 mm) tolerance.
[] 3" (7.6 cm) minimum dimension is from lower oven cutout
ceiling to microwave oven cutout floor.
[] Trim kit frame extends l_Ae" (2.7 cm) above and below the
cutout opening.
2
Loading ...
Loading ...
Loading ...