MAINTENANCE
VERY IMPORTANT SAFETY INFORMATION
ALWAYS clean the exterior of the Bio Air Scrubber Silver with a cloth and germicidal liquid. Change the
Filters whenever moving to a new location to prevent any contaminates from being carried from one
location to another.
WHEN TO CHANGE FILTERS AND UVC LAMPS
It is impossible to predict EXACTLY how long it will take for to become dirty enough to change. The
PRE-Filters should be changed after 30 days of light use in a clean environment, but any time you see
noticeable amount of dust and debris on them, they should be changed.
The HEPA filter has a pressure sensor on it that will light up when it needs to be changed.
It collects particles that are too small to be seen by the human eye, so a pressure reading is the best
indicator that HEPA performance has degraded and must be replaced.
The UVC Germicidal Lamps have a useful life of 8,000 hours, about 1 year of continuous use 24/7. They
will still emit UVC light, but the output drops o after about 1 year. Changing them after one year of
use is recommended. These UVC Germicidal Lamps have a built in Ballast, which is replaced with the
lamps for maximum reliability.
AIR EXCHANGE BASED ON ROOM SIZE
The size and number of machines depends on the volume of the space being cleaned as well as how
many Air Changes per Hour (ACH) are required by local regulation. As a starting point, calculate the
square footage of the room or rooms, multiply by the ceiling height. It is generally recommended to
have 3 to 4 air changes per hour in occupied areas
EXTRA LARGE ROOMS 30’ X 40’ X 8’ = 9600 CUBIC FEET = 3 EXCHANGES OF AIR PER HOUR
LARGE ROOMS 20’ X 40’ X 8’ = 6400 CUBIC FEET = 4 EXCHANGES OF AIR PER HOUR
MEDIUM ROOMS 20’ X 20’ X 8’ = 3200 CUBIC FEET = 8 EXCHANGES OF AIR PER HOUR
SMALL ROOMS 10’ X 10’ X 8’ = 600 CUBIC FEET = 32 EXCHANGES OF AIR PER HOUR
THE UVC LIGHTS INCLUDED IN
THE BIO SCRUBBER WILL CAUSE
PHYSICAL DAMAGE IF EXPOSED
TO EYES AND SKIN.
DO NOT TURN ON THE BIO
SCRUBBER WITH THE ACCESS
DOOR OPEN
Germicidal ultraviolet rays are harmful
to the eyes and skin. Always disconnect
power to the equipment and unplug
before performing any service or
maintenance. Do not operate without
proper electrical ground. To prevent the
risk of severe or fatal electrical shock,
special precautions must be taken.
Bio Air Scrubber Silver