920-010-06 (5-05)
Major
Components
IONIZER WIRES
IONIZER/COLLECTOR CELL
PRE-FILTER
CARBON FILTER
FRONT (LOGO SIDE)
HANDLE
IN REAR INDENTATIONS
C-90B
Specifications
OPERATING TEMPERATURES
This air cleaner is intended for use indoors, at temperatures normally found in occupied
spaces.
ELECTRICAL RATINGS
120 Volt, 60 Hertz.
INDICATOR LIGHT
Located on the access cover next to the 3-speed switch, It indicates that the air cleaner is
operating properly,
INTERLOCK SWITCH
Interrupts the supply power to the unit when the access cover is opened.
WEIGHT
33 Ibs, (15 Kg) shipping weight - 28 Ibs, (13 Kg) net weight,
DIMENSIONS
Height Width Depth
Cabinet 19" 15" 21 1/2"
NOMINAL CURRENT AND
POWER CONSUMPTION
120Volt. 60 Hertz
Fan Speed CFM Amps Watts
Hi.qh 390 .80 90
Medium 280 .56 64
Low 220 .41 47