Panasonic KE36NKU Wall Mounted Air Conditioner Cooling Area,

User Manual - Page 2

For KE36NKU.

PDF File Manual, 3 pages, Read Online | Download pdf file

KE36NKU photo
Loading ...
Features
Controls Microprocessor
Remote Controller LCD Wireless Type, Temp. Sensor
Built In
Temperature Control IC Thermistor
Timer 24 Hour, Single Event, ON/OFF
TIMER
Night Setback Included
Unoccupied Mode Included
High Power Included
One Hour Timer Included
Options
Refrigerant Line Set Available
Fresh Air Intake N/A
Airduct Extension N/A
Hard Wired Remote Control Available / Model Number-CZ-
RD515U
Indoor Frame Extension N/A
Condensate Drain Pump Available
Non-Removable, Locking
Remote-Control Bracket
Available
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max) 95F DB/71F WB 115F DB
Cooling (Min) 67F DB/57F WB 0F DB
Heating (Max) 80F DB/67F WB 75F DB/65F WB
Heating (Min) -DB/-WB 0F DB
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity (BTU/H) 34,000 (10,900-34,000)
Sensible Capacity (BTU/H) 20,700
Latent Capacity (BTU/H) 13,300
SEER 16
Dehumidification (Pints/H) 10.64
Amps (A) 5-21.9
Power Inputs (W) 4,000
Outdoor Sound Rating (dB-A) 55
Heating
Total Capacity (BTU/H) 36,000 (14,000-36,000)
HSPF 9,0
Amps (A) 5-21.9
Max Amps 18.2/19.9
Power Inputs (W) 3,650/3,650
Outdoor Sounds Rating (dB-A) 56
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Air Louver, Horizontal Manual
Air Louver, Vertical Automatic,Sweep,Step
Power Failure Automatic Restart Included
Heating/Cooling Automatic
Changeover
Included
Self-Diagnosis Included
Air Filter Washable, Anti-Mold
Loading ...