1. Indoor unit.
The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten
the remote controller range,
8)
the unit is at least 3.5ft (1m) away from any television or radio set (unit may cause interference with the picture or sound),
9) install at the recommended height (6ft (1.8m)).
2. Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are
properly received by the indoor unit (within 23ft (7m)).
2) Make the DIP switch settings. Set according to the type of unit purchased by the customer. The default settings
are on the heat pump side.
For cooling only (Outdoor unit model: RKS)
Set the DIP switch on the cooling only side.
For heat pump (Outdoor unit model: RXS)
Check that the DIP switch are on the heat pump side.
If they are set on the cooling only side, move them to the heat pump side.
• Before choosing the installation site, obtain user approval.
A
B
C
D
E
F
G
H
J
K
M
11
192
13
1
2
33
Mounting plate
Titanium Apatite Photocatalytic
Air-Purifying Filter
Wireless remote controller
Remote controller holder
Dry batteries AAA. LR03
(alkaline)
Fixing screws for remote controller
holder 1/8” × 13/16”L (M3 × 20L)
Operation manual
Screw cover
L
Installation manual
Mounting plate fixing screws
3/16” × 1”L (M4 × 25L)
Tube
1
Indoor unit fixing screws
3/16” × 1/2”L (M4 × 12L)
Accessories
Choosing an Installation Site
DIP switch
Heat pump
Cooling only
DIP switch
Heat pump
Cooling only
Loading ...
Loading ...
Loading ...