TROUBLESHOOTING
Before servicing the dryer, always check out the
machine to substantiate the complaint for which the
service call was created. In many cases, it may just be a
customer-instruct problem.
Will not run
Power supply
Check line fuses and line switches.
Main wiring harness
Check for loose or broken terminal.
Door switch
Make continuity check on switch contacts.
Main motor
Check motor.
Timer
Make continuity check on timer contacts Y to BG.
PUSH TO START button
Check start switch for continuity.
Power relay
Check power relay for open coil or bad contacts.
Clothes not drying
Operating thermostat
Check for open switch contacts.
Main motor
Check motor centrifugal switch M2 to M3 for open
contact.
Timer
Check timer switch contacts Y to R for continuity.
Also Y to BR, if used on timer.
Main wiring harness
Check for voltage at 1V, 2V, and 3V. Check harness
for shorted or broken wire.
Drum belt
Check belt. May be worn, broken, or off pulley. Faulty
idler assembly.
Drum seals
Check front and rear drum seals. Must be properly
positioned on the drum and flange surface.
Exhaust fan
Check fan for proper RPM, lint.
Gas burner
Check for function.
Lint screen
Check lint screen for lint.
Exhaust vent
Check exhaust vent for lint blockage.
Power supply
Check line fuses and switches.
Load
Check for size and type of load.
Improperly grounded
Check for control panel being grounded.
Drum will not rotate
Drum belt
Check for broken belt. Be sure it is properly posi-
tioned on motor pulley.
Will not shut off
Timer
Check timer motor for function and timer for welded
contacts.
Operating thermostat
Check for correct thermostat in dryer. Check for
failed thermostat.
Blowing fuses
Electrical ground
Check motor, electrical components, and harness
for ground.
Fuse box
Defective fuse-box assembly. Improperly fused.
Moisture retention unsatisfactory
Blocked exhaust
Inspect exhaust system for lint.
Thermostats
Check reason for improper cycling.
Improperly grounded control panel
Check grounding of control panel.
Will not heat
Main wiring harness
Check main harness at element terminals.
Operating and high limit thermostats
Install jumper across terminals and test dryer,
or make continuity test on switch contact.
Main motor
Check motor centrifugal switch 2M to 3M for
continuity.
Timer
Check continuity of timer contacts Y to R.
Also Y to BR if used on timer.
Gas burner
Check for function.
Power supply
Check line fuses and switches.
No gas flow
Check for closed gas supply valves.