Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes
after starting.
DONOTconnect240Voltloadsto 120Volt receptacles.
DO NOTconnect 3-phase loadsto the generator.
DO NOTconnect 50 Hz loadsto the generator.
Plug in andturn on the desired 120 Volt AC,single phase,
60 Hertz electrical loads.
DO NOTOVERLOADTHEGENERATOR.SeeDon't
Overload Generator.
NOTICE
Exceedinggenerators wattage/amperagecapacitycan
damagegenerator and/or electrical devicesconnected to it.
DONOTexceedthe generator'swattage/amperagecapacity.See
Don't OverloadGeneratorinthe Operationsection.
Startgeneratorandletenginestabilizebeforeconnecting
electricalloads.
Connectelectricalloadsin OFFposition,thenturn ONfor
operation.
TurnelectricalloadsOFFand disconnectfrom generatorbefore
stoppinggenerator.
Stopping the Engine
1. Turnoff and unplugall electricalloadsfrom unit.NEVER
start or stop engine with electrical devices plugged in
and turned on.
2. Let engine run at no-load for two minutes to stabilize
unit's internal temperatures.
3. Move engine rocker switch to "Off" position.
WARNING
Backfire,fire or engine damagecould occur.
DONOTstopenginebymovingchokeleverto "Cheke"position.
4. Move fuel valve to "Off" position.
CORDSETSAND RECEPTACLES
Useonly high quality, well-insulated, grounded extension
cords with the generator's 120 Volt duplex receptacle.
Inspect extension cords before each use.
Checkthe ratings of all extension cords before you use them.
Extensioncord sets used should be rated for 125 Volt AC
loads at 20 Amps or greater for most electrical devices.
Some devices, however, may not requirethis type of
extension cord. Checkthe operator's manuals of those
devicesfor the manufacturer's recommendations.
Keepextension cords as short as possible to minimize
voltage drop.
WARNING
_ verloaded electrical cords can overheat, arc,
and burn resulting in death, bodily injury, and/or
property damage.
ONLYusecords ratedfor your loads.
. Followall safetieson electricalcords.
120/240 Volt AC, 30 Amp, LockingReceptacle
Usea NEMAL14-30 plug with this receptacle. Connect a
4-wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater). You can use the same 4-wire cord if you plan to
run a 120 Volt load.
4-WireCordSet
:Neutral)
Y (Hot) | X (Hot)
NEMAL14-30 /-7L/ Ground(Green)
This receptacle powers 120/240 Volt AC,60 Hz,single phase
loads requiring up to 6,300 watts of power (6.3 kW) at
26.2 Amps for 240 Volts or two independent 120 Volt loads
at 26.2 Amps each.The outlet is protected by a double pole
rocker switch circuit breaker.
NOTICE
Receptaclesmay be marked with rating value greater than
generator output capacity.
NEVERattemptto powera devicerequiringmoreamperage
thangeneratoror receptaclecansupply.
DONOToverloadthe generator.SeeDon't OverloadGenerator.
12