Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this troubleshoot-
ing guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby’s Toll Free Number 1-800-263-2629 for assistance.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
Unit does not work Power is out
The plug is not plugged in prop-
erly
Plug current device tripped
Control is off
Wait for power to return
Plug in properly
Press the reset button after
resolving problem
Turn control ON and set to de-
sired setting
Air from unit does not feel cold
enough
Room temp. below 17°C (62°F)
Temp. sensing element touching
cold coil (behind air lter)
Temp. set too high
Compressor shut off by changing
modes
Will not cool until room temp.
rises above 17°C (62°F)
Straighten tube away from coil
Reset to a lower temp.
Wait approx. 3 minutes and
listen for compressor to restart
when in cool mode
Air conditioner cooling but room
is too warm- ice forming on cool-
ing coil behind decorative front
Outdoor temp. below 17°C
(62°F)
• Air lter may be dirty
Thermostat too cold for night-
time cooling
To defrost coil, set to FAN ONLY
• Clean lter as per instructions
Set temp. to a higher setting
Air conditioner cooling but room
is too warm- NO ice forming on
cooling coil behind decorative
front
• Dirty air lter - air restricted
Temp. is set too high
Air directional louvers positioned
improperly
Front of unit blocked (i.e. by
drapes), restricting air distribu-
tion
Doors, windows, registers etc.
open, cold air escaping
Unit recently turned on in hot
room
• Clean air lter
Set to lower temp.
Position louvers for better air
distribution
Clear blockage in front of unit
Close doors, windows, registers
allow additonal time to remove
“stored heat” from room
Air conditioner turns on and off
rapidly
• Dirty air lter - air restricted
Outside temp. extremely hot
• Clean air lter
Set fan speed to higher setting
to bring air past cooling coils
more frequently
Noise when unit is cooling Air movement sound
• Window vibration
This is normal. If too loud, set to
slower fan setting
Poor installation-refer to instal-
lation instructions or check with
installer
Water dripping INSIDE when unit
is cooling
Improper installation Tilt air conditioner silghtly to the
outside to allow water drainage
Water dripping OUTSIDE when
unit is cooling
Unit removing large quantity of
moisture from humid room
This is normal during excessive-
ly humid days
Remote sensing deactivating
prematurely
Remote control not located with-
in range
Remote control signal obstructed
Place remote control withing 8
meters (20 Ft.) and 180° radius
of front of the unit
• Remove obstruction
Room too cold Set temperature too low Increase set temperature
19