Installation must follow these codes:
s Local, state, provincial, and national codes, laws, regulations and ordinances.
s National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
s National Electrical Code, ANSI/NFPA 70 – latest edition, and/or the Canadian Electrical Code
Part I, CSA C22.1, Electrical Code.
s Canadian installations must comply with the Natural Gas and Propane Installation Code,
CAN/CSA B149.1 or B149.2 Installation Codes.
s Where required by the authority having jurisdiction, the installation must conform to the
Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME
CSD1.
The equipment shall be installed in accordance with those installation regulations in force in
the local area where the installation is to be made. These shall be carefully followed in all cases.
Authorities having jurisdiction shall be consulted before installations are made.
Commonwealth of Massachusetts
When the boiler is installed within the Commonwealth of Massachusetts:
s 4HISPRODUCTMUSTBEINSTALLEDBYALICENSEDPLUMBER
s )FANTIFREEZEISUSEDAREDUCEDPRESSUREBACKmOWPREVENTERDEVICESHALLBEUSED
Certification
Safe operating and other performance criteria were met with the gas manifold
and control assembly provided on boiler when boiler underwent tests specified
in ANSI Z21.13 - latest edition.
Before locating the boiler:
Check for nearby connection to:
s6ENTINGCONNECTIONS
s'ASSUPPLYPIPING
s%LECTRICALPOWER
Check area around boiler. Remove any combustible materials, gasoline and other flammable
liquids.
Failure to keep boiler area clear and free of combustible materials, gasoline and
other flammable liquids and vapors can result in severe personal injury, death or
substantial property damage.
Boiler must be installed so that gas control system components are protected from dripping
or spraying water or rain during operation or service.
If new boiler will replace existing boiler, check for and correct system problems, such as:
s3YSTEMLEAKSCAUSINGOXYGENCORROSIONORSECTIONCRACKSFROMHARDWATERDEPOSITS
Glycol — potential fire hazard —
All glycol is flammable when exposed to high temperatures. If glycol is allowed to accumulate
in or around the boiler or any other potential ignition source, a fire can develop. In order to
prevent potential severe personal injury, death or substantial property damage from fire and/
or structural damage:
s .EVERSTOREGLYCOLOFANYKINDNEARTHEBOILERORANYPOTENTIALIGNITIONSOURCE
s -ONITORANDINSPECTTHESYSTEMANDBOILERREGULARLYFORLEAKAGE2EPAIRANYLEAKSIMMEDI-
ately to prevent possible accumulation of glycol.
Codes CKeFNlLst
EG
&
PEG SERIES 5
s
EGH SERIES 5 GAS-FIRED BOILERSBOILER MANUAL