Greenlee CS-8000 Circuit Seeker Circuit Tracer

INSTRUCTION MANUAL - Page 16

For CS-8000.

PDF File Manual, 48 pages, Read Online | Download pdf file

CS-8000 photo
Loading ...
Loading ...
Loading ...
16
Maintenance
Electric shock hazard:
Do not attempt to repair this unit. It contains no user-serviceable parts.•
Do not expose the unit to extremes in temperature or high humidity. Refer to •
“Specifications.”
Failure to observe these precautions may result in injury and can damage the unit.
Battery Replacement
Electric shock hazard:
Before opening the case or battery compartment, remove the test leads from the circuit and
shut off the unit.
Failure to observe this warning could result in severe injury or death.
Disconnect the unit from the circuit. Turn the unit off.1.
Remove the screw from the battery cover.2.
Remove the battery cover.3.
Replace the batteries (observe polarity).4.
Replace the cover and the screw.5.
Cleaning
Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or
solvents.
Replacement Parts
Cat./UPC No. Description Qty Cat./UPC No. Description Qty
12849
Transmitter unit
1 12853
Extension lead
2
12850
Receiver unit
1 10054
AC blade
1
12851
Carrying case
1 10057
Alligator clip
2
12852
AC plug adapter
1