Fisher & Paykel CPV3366N 36 Inch Gas Rangetop with 6 Dual Fl

User Manual - Page 9

For CPV3366N.

PDF File Manual, 16 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
9
CABINETRY DIMENSIONS
48" CABINETRY
CLEARANCES
CLEARANCE DIMENSIONS
ALL MODELS
INCHES MM
A Min. distance from side of rangetop to nearest:
z
vertical combustible surface 12 305
B Min. distance from cook surface to overhead:
z
combustible surface 54 1372
z
combustible covering for ventilation hood 36 914
z
non-combustible surface 30 762
C Min. distance between countertop and cabinet 18 457
D
E
C
B
A A
C
Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-
combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6" (152mm) must
be approved by the local codes and/or by the local authority having jurisdiction.We recommend mounting the regulator at the cooktop and using Flex gas line. Refer to page 12 for details
The below clearances apply to both wall and island installations for all models.
Ensure the cook surface sits flush or above the adjacent countertop and any openings behind
or under the rangetop are sealed. Flow of combustion and ventilation air must not be obstructed.
Ensure the cooktop is adequately supported from the bottom.
CABINETRY DIMENSIONS
30" MODELS
INCHES MM
A Max. height 8 203
B Depth
z
Flush with counter 26 5/8 677
z
Projecting control panel 24 3/16 614
C Width 48 1219
D Max. depth of overhead cabinetry 13 330
E Min. width of ventilation hood required 30 762
F Width of gas inlet and power cord cut-out 12 305
G Depth of gas inlet and power cord cut-out 8 7/16 215
B
C
A
f
g