Exhausting cooker hood. The equipment is constructed in
accordance with European Standards and with the requirements
included in the following Directives: 2006/95EC ( Low Voltage
Directive), 2004/108 (Electromagnetic Compatibility).
1 INSTALLATION
Read the instruction manual before installing and/or using the
hood .
In order that the minimum distance between the supporting
surface for the cooking pots on gas hob and low-voltage
components present in the hood is at least 65cm as required by
the regulations in force, it is necessary that the lower part of the
hood is at least 60cm away from the work top.
If the mounting instructions of the gas cooker indicate a wider
distance, respect it. The unit must not be mounted above cookers
tted with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge
exhaust fumes produced by gas- fed equipments or fuel-fed
equipments (this does not apply to ltering hoods).
The room must be adequately ventilated when the hoods is used
together with other gas-fed or fuel-fed equipments.
The hood is equipped with all the necessary fastenings for its
installation, which are suitable for most surfaces. Anyway, ask
to a professional to verify that the installation surface is strong
enough. Installation must be carried out by qualied installers
according to present regulations.
For an easy access, it is advisable to move possible furniture
under the installation area. For mounting the hood follow the
illustrations in Fig. 1.
To remove the bottom panel follow the illustrations on Fig. 2
To install the cover follow illustrations on Fig. 3
2 ELECTRICAL CONNECTIONS
This equipment must be connected to a grounding plant. Two
types of electrical connection can be used:
Using a standard plug to be connected to the power cable
and inserted in a mains socket which must be accessible (so
that the plug can be disconnected when servicing is carried
out). Make sure that the plug is accessible also after the
complete installation of the equipment.
By means of a xed mains connection, tting a bipolar
switch, which ensures the disconnection, with an opening
distance of the contacts allowing a complete disconnection
on the conditions of the overvoltage III category, according
to installation regulations. The ground connection (yellow-
green wire) must not be interrupted.
Refer to the plate inside the hood for the mains voltage and
frequency ratings.
3 USE
This cooker hood can be employed as exhausting or ltering.
Exhausting (Fig. 4). The carbon lters should not be installed on
the hood in exhausting version.
Kitchen smokes are driven outside through a ue joined to the
exhaust pipe ue connector..
Pipes must be communicating with the exterior of the house. The
diameter of the outlet of the hood is 150mm. A 150-125 reduction
is provided with the hood.
This pipe must not under any circumstances be connected to
cooker, boiler or burner exhaust pipes, etc.
Filtering (Fig. 5). The fumes pass through the carbon lters to be
puried and recycled into the kitchen through a pipe connected
to the outlet of the hood up to the hole on the top of the cabinet.
This hole must be free and communicating with the kitchen.
In the ltering version you must install the two carbon lters on
the sides of the aspirator. To install the carbon lters you must
rst remove the metal grease lters (Fig. 6) and then install
carbon lters by turning them counterclockwise (Fig. 7).
4 OPERATION
The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions
and at higher speeds only when there is a heavy build-up of
fumes or odours.
Ideally, the hood should be switched on as soon as cooking is
started and then kept on until all odours have been eliminated.
The controls consist of these commands. Press TL to turn on the
light, press T1 to swich on the hood at rst speed and to switch
off the aspirator, press T2-T3-T4 to select functioning speeds.
By pressing of the command T1 the motor starts running at the
1st speed. The commands
T2-T3-T4 switch the motor on respectively at the 2nd, 3rd and
4th speed. In order to switch the motor off press T1 once if set
at the 1st speed, twice if set at the 2nd, 3rd and 4th speed. With
the button T4, select the maximum speed of the extraction fan
for 5 minutes (LED blinking), after which the extraction fan will
automatically switch to the 3rd speed.
Adjustable and delayed self switching off
While the hood is working, keep the TL command pressed until
all LEDs start blinking. By pressing one of the LEDs (T1, T2, T3,
T4) you can program the delayed self switching off, as follows:
T1 corresponds to 5 minutes
T2 corresponds to 10 minutes
T3 corresponds to 15 minutes
T4 corresponds to 20 minutes
During the time of the self switching, you can change and set
any speed.
Filters maintenance reminder
Aluminium anti-grease lters
Once the hood is switched off, after 30 hour functioning, all the
leds of the speed LEDs switch on with a xed light for 30 seconds
to remind that aluminium anti-grease lter need cleaning.To set
the timer to zero, keep the button T4 pressed with the aspirator
switched off, otherwise the timer will remain set on 30 hour
functioning and the reminder will occur again when the hood is
switched off again.
Charcoal lter (for ltering hoods)
Once the hood is switched off, after 120 hour functioning, all
LEDs blink for 30 seconds to remind that the charcoal lter need
cleaning.
To set the timer to zero, keep the button T4 pressed with the
aspirator switched off, otherwise the timer will remain set on
120 hour functioning and the reminder will occur again when the
hood is switched off again.