INSTALLATION OF DISPENSING EQUIPMENT
(continued)
10. On the right rear sidewall there is a
double column of screws. Remove
the left screw. Locate the safety
chain and a #10 x 1/2ā€ sheet metal
screw from the parts bag. Insert the
screw through the closed end link of
the chain and tighten in the vacant
screw hole. The chain can now be
used to secure the CO
2
cylinder with
ā€œSā€ hook, preventing damage to the
regulator.
11. CO
2
cylinders are shipped empty
and must be filled prior to use. Turn
the adjusting knob on the regulator
counter-clockwise until the outlet
pressure gauge (top) reads zero. Make
sure that the valve at the bottom of
the regulator where the red hose is
connected, is in the OFF position
as shown on page 18. Watching
the outlet pressure gauge, turn the
regulator adjusting knob clockwise
until the pressure is at 15 psi.
Adjustments can later be made based
on flow rates.
12. Locate the beer faucet(s) and install
onto the dispensing head shanks.
Tighten with supplied spanner wrench.
Install black handle(s) onto faucet(s).
IMPORTANT: All pressure adjustments
MUST be made when the shut-off valve is
in the OFF position!