1 Foil & Cutter cassette
2 Cassette release buttons
3 Multi Head Lock switch
4 On / off button
5 Shaver display**
5 a Travel lock
5 b Replacement indicator for Foil & Cutter cassette
5 c Status segments
5 d Minutes left display
5 e Cleaning indicator*
5 f Plug reminder 5g Battery icon*
6 Precision trimmer
7 Shaver-to-station contacts
8 Release button for precision trimmer
9 Shaver power socket
10 Power supply**
10 a Charging stand*/**
11 Travel case
* not with all models (see display box)
** design can differ For electric specifications, see printing on the power supply
Battery status

The battery status is shown with segments and additionally in digits (for some models also with a battery icon).
Plug reminder (low charge / cordless operation only)

Travel lock

Replacement indicator for Foil & Cutter cassette

Cleaning indicator (with Clean & Charge station usage only)

Make sure that the shaver is disconnected from the power supply. Press the on / off button (4) to operate the shaver.
Tips for a perfect shave
Multi Head Lock switch (head lock): The shaver head can be locked in five positions to shave hard-to-reach areas (e.g. under the nose).
Precision trimmer: The trimmer can be used to trim sideburns, moustache or beard.
Travel lock: The shaver can be locked to avoid unintended starting of the motor (e.g. for storing in a suitcase).
Foil replacement: To maintain 100% shaving performance, replace the Foil & Cutter cassette (1), when the foil replacement indicator lights up and no status segments are visible.
Cleaning under running water: Especially important after foam or gel usage
The shaver needs to be cleaned under running water after each foam or gel usage!
Cleaning with a brush
The Clean & Charge Station has been developed for cleaning, charging, lubricating, drying and storing your Braun shaver.
Important
Do not refill the cartridge and use only original Braun refill cartridges.
DANGER : FLAMMABLE. CONTENTS MAY CATCH FIRE. Do not smoke. Use only in well-ventilated areas. Keep away from flames such as pilot light, and any object that sparks such as electric motor. Keep locked up. KEEP OUT OF REACH OF CHILDREN. CAUTION : MAY IRRITATE EYES. Do not get in eyes. FIRST AID TREATMENT: Contains ethanol. If swallowed, call a Poison Control Centre or doctor immediately. Do not induce vomiting. If in eyes, rinse with water for 15 minutes.
12 Station power socket
13 Lift button for cartridge exchange
14 Station-to-shaver contacts
15 Clean & Charge Station display
15 a Level indicator
15 b Status light
15 c Cleaning program indicators*
16 Start button
17 Cleaning cartridge*
* not with all models (see display box)
Important: The shaver needs to be dry and free from any foam, gel or soap residue!
Charging the shaver in the C & C: Charging will start automatically when the shaver has been inserted properly.
Cleaning the shaver in the C & C: When the cleaning indicator lights up on the shaver display, insert the shaver into the C & C, as described above.
Cleaning programs (not with all models)
short / economical cleaning
normal level of cleaning
intensive cleaningAutomatic cleaning: Start the cleaning process by pressing the start button (16). If status light (15b) does not shine (C & C switches to stand-by after ca. 10 minutes), press start button twice. Otherwise, cleaning will not start
Depending on your model and / or program selected, the cleaning time takes up to 3 minutes and afterwards a fan runs. During this time the status light (15b) blinks.
After cleaning, drying and charging is completed, all indicators turn off
Removing the shaver from the C & C
| Problem | Possible reason | Remedy |
| Shaver does not start when pressing the on / off button. |
1. The shaver can only be operated cordless. 2. Travel lock is activated. |
1. Unplug the shaver. 2. Press the on / off button for 5 seconds to unlock the shaver. |
| Charging does not start when connected to power socket or put in the Clean & Charge Station. |
1. Sometimes charging starts delayed (e.g. after long storage). 2. Ambient temperature is out of valid range. 3. Power supply is not plugged into the shaver properly. 4. Shaver is not placed properly in the Clean & Charge Station. |
1. Wait a few minutes. Charging will start automatically. 2. Recommended ambient temperature for charging is 41 °F to 95 °F / 5 °C to 35 °C. 3. Power supply needs to snap in. 4. Contacts of the shaver need to align with contacts in the Clean & Charge Station. |
| Shaver does not charge completely and keeps blinking. | Ambient temperature is out of valid range. | Recommended ambient temperature for charging is 41 °F to 95 °F / 5 °C to 35 °C. |
| Unpleasant smell from the shaver head |
1. Shaver head is cleaned with water. 2. Cleaning cartridge is in use for more than 8 weeks. |
1. When cleaning the shaver head with water only use hot water and from time to time some liquid soap (without abrasive substances). Remove Foil & Cutter cassette to let it dry. 2. Change cleaning cartridge at least every 8 weeks. |
| Battery performance dropped significantly. |
1. Foil and cutter are worn which requires more power for each shave. 2. Shaver head is regularly cleaned with water but not lubricated. |
1. Renew Foil & Cutter cassette. 2. If the shaver is regularly cleaned with water, apply a drop of light machine oil on top of the foil once a week for lubrication. |
| Shaving performance dropped significantly |
1. Foil and cutter are worn. 2. Shaving system is clogged. |
1. Renew Foil & Cutter cassette. 2. Soak the Foil & Cutter cassette into hot water with a drop of dish liquid. Afterwards rinse it properly and tap it out. Once dry apply a drop of light machine oil on the foil. |
| Shaver head is damp. |
1. Drying time after automatic cleaning was too short. 2. Drain of the Clean & Charge station is clogged. |
1. Wait until the drying process has been completed. 2. Clean the drain with a wooden toothpick. |
| Problem | Possible reason | Remedy |
| Cleaning does not start when pressing the start button. |
1. Shaver is not placed properly in the Clean & Charge Station. 2. Cleaning cartridge does not contain sufficient cleaning fluid (display blinks red). 3. Appliance is in stand-by mode.. |
1. Insert shaver into the Clean & Charge Station and push it to the rear side of the station (contacts of the shaver need to align with contacts in the station). 2. Insert new cleaning cartridge. Press the start button again. 3. Press the start button again. |
| Increased consumption of cleaning fluid. | Drain of the Clean & Charge station is clogged. |
– Clean the drain with a wooden toothpick. – Regularly wipe the tub clean. |
Reference file: Braun 9477CC Series 9 Pro Electric Shaver with PowerCase
Series: Series 9
Additionally, the document applies to other Braun models: 5793, 93XXCC, 93XXS