TROUBLESHOOTING
Mode Description
Engine will not start
Engine Switch is “O” Set engine switch to “run”
Fuel Valve is “Closed” Turn fuel valve to “open”
Choke is open. Close the choke
Engine is out of fuel Add fuel
Fuel is old or contaminated Change fuel
Spark Plug is dirty Clean spark plug
Spark Plug is broken Replace spark plug
Generator is not level
Move generator to a level
surface
Oil is low Add / change oil
Engine runs, but there
is no electrical output
Circuit breaker is “O” Turn “on” circuit breaker
Wiring connection is bad Replace extension cord(s)
Device connected to generator
is malfunctioning
Disconnect malfunctioning
device
Generator runs, but
does not support all
electrical devices
connected
Generator is overloaded.
Disconnect 1 or more items to
reduce the load
Device connected to generator
is bad
Disconnect malfunctioning
device
Air Cleaner is dirty Clean / replace the air lter