Kenmore 3ES135 boiler

User Manual - Page 20

For 3ES135.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
BOILER
MODEL
3ES1.00(C)
3ES1,25(0)
3ES! .35(C)
4ES1,50(C)
4ES1,75(C)
4ES1,85(0)
SUGGESTED NOZZLES AND SETTINGS
FOR BECKETT AFG-M OIL BURNER SERIES
NOZZLE ACTUAL
0,85-60°W 1.00
1,10-70°B 1.25
1,20-70°B 1.35
1,25-60°B 1.50
1,50-60°B 1.75
1.75-60°B 1.85
PUMP
PRESSURE
(psig)
!40
140
!40
140
140
140
HEAD
ADJUSTMENT
1
1
1
3
3
AIR
SHUTTER
10
10
10
I0
10
10
AIR
BAND
1
1
2
2
3
4
OIL
BURNER
MODEL
AFG-50MB
AFG-50MD
AFG-50MD
AFG-50MD
AFG-50MD
AFG-50MD
FOR RIELLO R40 OIL BURNER SERIES
ACTUAL PU MP AI R OIL
BOILER NOZZLE TURBULATOR
MODEL (DELEVAN) INPUT PRESSURE SETTING GATE BURNER
RATE (gph) (psig) SETTING MODEL
3ES1,00(C) 0.85-60°W 1.00 150 2,0 3.00 F5
3ES1,25(C) 1.00-60°W 1.25 165 2.5 3.60 F5
3ESl.35(C) 1.10-60°W 1.35 165 3.5 4.25 F5
4ES1.50(C) 1.25-60°W 1.50 160 1.5 2.60 FIO
4ES1.75(C) 1.50-60°W 1.75 145 1,5 3.25 FIO
4ES1.85(C) 1.50-60°W 1.85 160 2.0 3.40 FIO
FOR CARLIN EZ OIL BURNER SERIES
BOILER NOZZLE I HEAD
[
MODEL (DELEVAN) ! SETTING
3ES1.00(C)
3ES1,25(C)
3ES1.35(C)
4ES1.50(C)
4ES1,50(C)
4ES1,65(C)
4ES1,85(0)
0.85x70ow
1.00x70°W
1, !Ox70°W
1.25x60°W
1,25x60°W
1.35x60°W
1,50x60°W
ACTUAL
INPUT
RATE (gph)
1.00
1.25
1.35
1.50
1.50
1.65
1.85
PUMP
PRESSURE
(psig)
150
150
150
150
150
150
150
0.85-1.00
0.85-1.00
1,10-1.25
1.10-1.25
0.85-!.00
1.50
! ,50
AIR BAND
SET
POINT
0.65
0.90
1.!0
1,10
1,65
1.65
2.00
OIL
BURNER
MODEL
EZ-1 HP
EZ-1 HP
EZ-I HP
EZ-1 HP
EZ-2 HP
EZ-2 HP
EZ-2 HP
All burners fired at an over fire pressure of -0,02"wc.
Burner insertion depth of 2-1/8" allows burner tip to
be 1/4" behind insulation, I NOTE: These settings are intended for ini-
I
tial start up only, Final adjustment must be
!
made using combustion test instruments, i