Hotpoint HSS25GFTJBB refrigerator - t series

User Manual - Page 19

For HSS25GFTJBB.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Performance Data Sheet
SmartWaterFiltration System
MWF Cartridge
This system has been tested according to NSF/ANS142/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142/53.*
'100%safety factors built in for unmetered usage)
Stmldard No. 42: Aesthetic Effects
Parmneter USEPA hlfluent
MCL CJlalle_e ConcenWafion
Chlorine -- 2.0 mg/L + 11)%
T&O -- --
Pmliculate** -- _>10,000 parddes/mI,
Influent
Average
1.96 mg/I,
I
6,400,01_)#/mL
Effluent
Average Maxhnmn
0.06 rag/I, 1).11 rag/I,
I I
58,833#/mI, 150,(_)0#/mI,
% Reduction
Average Minimmn
96.77% 94.74%
I I
9{).14% 97.{)7%
Mill. Required
Reduction
> 50%
_>85(/(,
Standard No. 53: Health Effects
Pariuneter
"litrbkiity
(iysl+
Asbestv)s
Lead at pit 6.5
Lead at pit 8.5
Metvtt U at Ill { 6.5
Met*:ttU at Ill t 8.5
,\ladfior
[ hi(lane
2,4-1)
"Ibxat)hene
Bel/zel/e
Carbofimm
1,4 di&lorobenzene
Mrazine
USEPA
MCL
0.5 NTL
_>9{).{!5%Reduction
_>99% Re(ht(tion
t).t)15 mg/L
t).t)15 mg/L
0.002 mg/L
0.002 mg/L
0.002 rag/I,
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
t).t)75 mg/L
0.003 rag/I,
hffluent
Challe_ ,_ge Concentration
11 k I NqT ***
Mflfimum 50,(X)0 I,
1(F to 1(Js fib( e_!I,; > 10[lm
0.15 rag/I,_+ 1()f_
0.15 rag/I,_+ 1()f_
0.006 mg/L + 10!¢
0.006 mg/L + 10!¢
0.04 rag/I,_+ 10!¢
0.002 rag/I, ± l()f_
0.210 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
0.080 mg/I, + 10%
t).225 rag/I, + 10%
0.1)(_}rag/I, + 10%
hlfluent
Average
10.5 NTU
118,750 #/I,
57 MF/I,
0.1567 rag/I,
0.1433 mg/I,
0.(X)59 ra!!I,
0.(X)57 ra!!I,
0.0367 rag/I,
0.(X)20 ra!!I,
0.2033 rag/I,
0.0160 rag/I,
0.0145 rag/I,
0.0830 rag/I,
02283 rag/I,
0.0087 rag/I,
Effluent
Average Maxhnmn
0.14 NTU 0.28 N'IT
< 1 #/I, 4#/I,
t).9!)6 MF/I, < 1 MF/I,
<0.001 rag/I, <0.001 rag/I,
< 0.001 mg/L < 0.001 rag/I,
0.000350 mg/L 0.0007 mg/L
0.000325 mg/L 0.0006 mg/L
0.00023 rag/I, 0.0004 mg/L
< 0.00002 rag/I, < 0.(X)002 rag/I,
0.00337 rag/I, 0.011000 rag/I,
0.001(X) rag/I, 0.(X)I(X)0 rag/I,
0.0(X)5(X)rag/I, 0.(X)0500 rag/I,
0.001000 mg/L 0.001000 rag/I,
0.0(X)5(X)rag/I, 0.(X)0500 rag/I,
< 0.0005 rag/I, < 0.0005 mg/I
% Reduction
Average Minimmn
98.54% 97.20%
> 9!).!)9% > 9!).!)9%
99.(_0% 99.39%
99.36% !)9.2!)%
99.30% 99.29%
94.70% 87.50%
93.2t)% 8{).2!)%
9!).?.{% {)8.67%
99.(_)% 98.95%
98.32% 94.50%
93.44% 91.67%
96.51% !)5.83%
98.78% !)8.65%
9{).78% 99.77%
94.22% 93.33%
Tested using a flow rare of O.50 gpm; pressure of 60 psig; pH of Z 5 _+O.5; temp. of 68 ° _+5°F (20 ° _+3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU:Nephelometric Turbidity units
gperafing ,
Specifications
Ca I_a(itv" certified h)r, iu _ to ,:;00 ,("all°ns_ ( l 1:,:;5 1);, u ), to _,six
months for models without a rel_a(ement filter m_tl(ator hoht;
up to one ",ear for models with a replacement filter indicator hght
. •! , . c , c . '
P_ essm e I equn ement: 41)-120 psi (2.8-8.2 bat ), non-shock
Temperature: 33-1 00°F (0.6-38°C)
Flow rate: 0.5 gpm (1.9 lpm)
General Installat!on/Operation/Maintenance Requirements
Flush new cartridge at full fl(/w tilt 3 minutes to purge out
trapped aiI:
Replace cartridge when the indicator light flashes (/i" water
fl(/{v rate is i'e(hlced on heir-tied|cater tfifits.
Special Notices
Installation instructi(ms, parts and service axailabilitx; and standard
wail'ants' are iI_cluded with file product when shipped.
This di_nking water svsteln must be nlaintained according to
illantt[acttlr(_ias ii_strtlcOons, iI_duding replacen_ent of filter cartridges.
Do not ttse ;_Jfl/water filet is nficrobiol0gi(Sally unsafe or of unknown'
qualiPv without adequate cfisinfecfi(nl before or after file svstenl.
SvstelllS certified fi)i: cyst reduction inav be used (Ill disinfected water T0_VI_
tliat may contain filtelable cysts.
The contaminants or othei" substances removed or reduced by this
water treatinent svstein are not necessarily in your watei:
Check tot compliance with the state and local laws and regulations.
Note that while the testing was perIimned under standard lal)omtor_
conditions actual pell'Oii/lance ina _, x_u'v. S_,stelns inust be installed _uld
operated in accordance with inalm_actt/rei:'s recolmnei_ded procedures
and gtudehnes.
Standard No. 42: Aesthetic Effecis
Chemical [7nit
Chlorine 'Ihste and Odor
Mechanical Filtralion Unit
Parti(ulate Reduction, Class I
System "[-csted and Certified by NSF lnt( rnational against
ANSIiNSF StandaM 42 & 53 for the reduction of
Standard No. 53: Health Effecis
Chemical Reduction Unit
Alachh)r and Atrazine Reduction
Benzene and Carbofiwan Reduction
1,4 dichlorobenzene and 2,41) Reduction
Lead and Lindane Reduction
Mercm T and Toxaphene Reduction
Mechmfical Filtration [ nit
Tu rbidilv Rcdtlction
(:)st and ,\_,bestos Reduction
Mhl. Required
Redue6on
0.5 NTU
_>9{).{}5%
_>9!)%
0.010 rag/I,
0.010 rag/I,
0.002 rag/I,
0.002 rag/I,
0.002 rag/I,
0.0002 mg/I,
0.070 rag/I,
0.003 rag/I,
0.005 rag/I,
t).t)4mg/I
t).t)75rag/I,
0.003 rag/I,
Ratc, d Service ('apaciD: 300 gaI
Conditions of ( err|flea ti0n:
DO not use whele _,_atet 15 nlicl obiologically mtsafe ol vdfh'_ at_i of lulkllovcn qttallty, except that systems cedlfied fol
cy_l I edtlchon Inay h_ tlsed oi1 distil fected _Aatels ttla_ lllay colltaii1 fii_el at de cy_ls
Manufactured tk)r: (;en( ml El(cn-ic Company, Louisville, txN 40225
EPA EST. No. 070595-MN4101
/9
StaTe of Caliibmia
Dcpai_nlellt of Hcatth Selvlces
Water Treatment Device
Certificate Number
05- 1698
Da_cIssued: Febmal_ 2.2OO_
l'l'at[¢qnark/Mot[_,[ I)¢,si_nati0n lloplac_,rtlenl Element',
MWF MWF
Ma nufllct in'f,r: GeneraI Eiech'ic C01npa:ay
Loading ...
Loading ...
Loading ...