Operation
Thermostat
The Thermostat, see Fig.2 controls the heat output according to the room temperature.
This ensures that the heater will not produce heat unnecessarily when the room is
warm.
1. To set the temperature you require, turn the thermostat knob clockwise until the
required setting is reached. Alternatively to heat a cold room quickly, turn the
thermostat knob up fully.
2. When the room has reached the desired temperature, turn the thermostat knob
anti-clockwise until the thermostat just clicks o. The heater will now automatically
operate at this temperature.
3. The thermostat also has a frost protection setting marked '*' This setting is useful
in areas such as garages, to prevent frost damage. If the thermostat is set to its
minimum setting '*' the heater will cycle on and o to maintain a temperature of
approximately 5° to help protect against frost.
Note – Should the heater fail to come on when the thermostat is at a low setting, this
may be due to the room temperature being higher than the thermostat setting.
Heat Selector Switches (see Fig.3)
Heat selection is provided via a rotary switch oering four settings. The heat output
can be altered to suit the application, conditions and for improve the economy of
operation.
Available output options are as follows:
Switch setting
With
Turbo
ON
Only
Turbo
ON
Model O I II III
0CR15FA
O 500W 700W 1200W 1500W 300W
OCR24FA
O 900W 1200W 2100W 2400W 300W