DCS BH148RN 48 Inch BuiltIn Gas Grill with 1,182 Sq. In. Coo

User Manual - Page 24

For BH148RN.

PDF File Manual, 80 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
22
TO LIGHT THE GRILL BURNER:
Open the grill lid and/or remove the top grate cover from side burner (for BH1-48RS) before lighting. Turn all knobs to
“OFF”. Turn the main gas supply on. If you smell gas, shut-off gas supply and call for service.
Grill Lighting Instructions:
The grill knob is connected to the electronic ignition module. Pushing in on the burner knob will activate the igni-
tion module to get a spark.Push in and turn the selected burner knob to HI/SEAR position. Release the knob when
the burner lights. If burner does not light in 4 to 5 seconds, turn
knob “OFF” and wait 5 minutes before trying again so any accumu-
lated gas may dissipate.
Grill Match Lighting:
If the burner will not light after several attempts, then the burner
can be match lit. If you’ve just attempted to light the burner with
the ignition, allow 5 minutes for any accumulated gas to dissipate.
Keep your face as far away from the outdoor appliance as possible
and hold a paper book match over the hole located on the top left
for burner on the left, or the right hole for the right burner (Fig. 26 and Fig. 27). Push and turn the control knob
which is centered on the burner where the lit match is located, to “SEAR”. If the burner does not light in 4 seconds,
turn the knob off, wait 5 minutes and try again.
NOTE:
Improper lighting procedures can cause the LP tank flow control to activate, resulting in reduced heat output. If this is sus-
pected, to reset flow control, shut off all burner controls and LP cylinder valve, wait 30 seconds, then turn LP cylinder valve
on extremely slowly, wait five (5) seconds and push and hold the ignition
button and turn burner valve on to “SEAR”.
For BH1-48RGI and BH1-36RGI models see the Quick Start Guide for how
to use the griddle and Infrared Hybrid Burner
TO LIGHT DUAL SIDE BURNERS 48BQR MODELS ONLY:
CAUTION!
The side burner cover may be hot if the grill burners are in operation.
Side Burners Lighting Instructions:
First remove the burner cover and any cooking utensils from the
burner grate. The control knob is connected to the electronic igni-
tion module. Pushing in on the control knob will activate the ignition module
to get a spark. Push the control knob in and turn to “HI”. If burner does not
light in 4 to 5 seconds, turn knob “OFF” and wait 5 minutes before trying
again for any accumulated gas to dissipate. If the burner will not light after
several attempts, check the trouble shooting instructions on page 33.
Side Burners Match Lighting:
Hold a lit paper book match near the burner ports, turn the control knob
counterclockwise to “HI”. Move your hand immediately once the burner is
lit. Rotate the control knob to the desired setting.
Note:
If you are using propane gas, a slight pop or flash may occur at the burner ports a few
seconds after the burner has been turned “off”. This “extinction pop” is normal for
propane gas.
Side burners:
Your side burner is equipped with burners typical of those used in restaurants. These
burners are designed for maximum cleanability and controlability. The burner should
never be operated if the cap is not in place (Fig. 29).
USING THE GRILL
LIGHTING INSTRUCTIONS
FIG. 26
FIG. 27
FIG. 28
FIG. 29
Cap
Control Knobs
SEAR
OFF
All knobs must be in the OFF position before
opening LP tank valve.
Now open the LP tank valve two (2) full
turns min.
Failure to follow the steps in the order shown may cause the Flow
Limiting Device to activate resulting in extremely low gas ow and
improper operation.
Attach regulator hose assembly to tank.
WARNING
3
1
2
Loading ...
Loading ...
Loading ...