11
3. Remove the control box off the
mounting frame by unscrewing the
two screws on the supporters of the
control box. (Fig. 4)
Fig. 4
4. Install the assembled mounting frame
and the lower duct divider into the
rooftop opening. Make sure the “THIS
WAY FRONT” mark is facing front
(the direction of the vehicle) while
installing. (Fig. 5)
Fig. 5
5. Fix the assembled mounting frame
and lower duct divider into the rooftop
unit using 4 bolts provided. (Fig. 6)
NOTE: If bolts are left loose there
may not be an adequate roof seal or
if over tightened, damage may occur
to the rooftop base or mounting
frame. Evenly tighten the four bolts
to a torque of 40 to 50 inch pounds.
This will compress the roof gasket to
approximately ½”.
Mounting Hole
Fig. 6
6. Pull to remove the film off the double
sided sticky tape on the inner side of
the lower duct divider. (Fig. 7)
Film
Fig. 7
7. Stick the upper duct divider into the
assembled mounting frame.
NOTE: Make sure the upper duct
divider is pressing against the ceiling
before finally sticking it. (Fig. 8)
Upper Duct
Divider
Fig. 8