10
ELECTRICAL CONNECTION TO JUNCTION BOX
If local codes permit connecting the cabinet-grounding
conductor to the neutral (white) wire in the junction box:
1 Disconnect the power supply.
2 Remove the junction box cover.
3 Connect the oven cable to the junction box through
the U.L. listed conduitconnector.
4 Connect the two black wires together with
twist-on connectors.
5 Connect the two red wires together with twist-on
connectors.
6 Connect electrical connection according to local
codes andordinances.
7 Connect the factory-taped green and white oven cable
wires to the neutral (white) wire in the junction box.
8 Replace the junction box cover.
Four-wire electrical system
1 Disconnect the power supply.
2 Remove the junction box cover.
3 Connect the oven cable to the junction box through the U.L.-listed conduit connector.
4 Connect the two black wires together with twist-on connectors.
5 Connect the two red wires together with twist-on connectors.
6 Connect electrical connection according to local codes and ordinances.
7 Separate the green and white oven cablewires.
8 Connect the white oven cable wire to theneutral (white) wire in junction box.
9 Connect the green grounding oven cable wire to the (green) grounding wire in thejunction box.
Do not connect the green grounding wire to the neutral (white) wire in junction box.
!0 Replace the junction box cover.
If local codes DO NOT PERMIT connecting the cabinet-grounding
conductor to the neutral (white) wire in junction box:
1 Disconnect the power supply.
2 Remove the junction box cover.
3 Connect the oven cable to the junction box through the U.L.-
listed conduit connector.
4 Connect the two black wires together with twist-on connectors.
5 Connect the two red wires together with twist-on connectors.
6 Connect electrical connection according to local codes and
ordinances.
7 Separate the factory-taped green andwhite oven cable wires.
8 Connect the white oven cable wire to the neutral (white) wire
in junction box.
9 Connect the green grounding oven cable wire to a grounded
wire in the junctionbox.
!0 Replace the junction box cover.
Connection methods
MODEL VOLTAGE
MAX CURRENT
DRAW
MAX LOAD
OB30 Single 208 V 16.6 A 3.5 kW
240 V 19.4 A 4.6 kW
OB30 Double 208 V 33.2 A 7.0 kW
240 V 38.3 A 9.2 kW
a
B
cable from
power supply
Junction box locations
junction box
location for
undercounter
installation
junction box
location for
wall installation
cable from
power supply
box
black
wires
black
wires
red
wires
red
wires
green grounding
oven wires –
factory taped
white
wires
white and
green grounding
oven wires –
factory taped
U.L.-listed
conduit
connector
U.L.-listed
conduit
connector
Nameplate location