INJECTORS TABLE CATEGORY
II2H3+
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
kW
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Rapid
Semi-rapid
Auxiliary
115 Y
95 Z
72 X
3,00
1,65
1,00
286 l/h
157 l/h
95 l/h
0,70
0,40
0,40
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid
Semi-rapid
Auxiliary
85
63
50
3,00
1,65
1,00
218 g/h
120 g/h
73 g/h
0,70
0,40
0,40
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid
Semi-rapid
Auxiliary
85
63
50
3,00
1,65
1,00
214 g/h
118 g/h
71 g/h
0,70
0,40
0,40
25 37 45
Type of gas used Model conguration
4BURNERS
Rated thermal owrate
(kW)
Total rated
consumption
Air required (m
3
) for burning
1m
3
of gas
G20 20 mbar 1R - 2SR - 1AUX 7,30 695 l/h 9,52
G30 28-30 mbar 1R - 2SR - 1AUX 7,30 531 g/h 30,94
G31 37 mbar 1R - 2SR - 1AUX 7,30 521 g/h 23,80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6 W
INJECTORS TABLE (only for Malta) CATEGORY
II2H3B/P
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
kW
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Rapid
Semi-rapid
Auxiliary
115 Y
95 Z
72 X
3,00
1,65
1,00
286 l/h
157 l/h
95 l/h
0,70
0,40
0,40
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid
Semi-rapid
Auxiliary
85
63
50
3,00
1,65
1,00
218 g/h
120 g/h
73 g/h
0,70
0,40
0,40
20 30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid
Semi-rapid
Auxiliary
85
63
50
3,00
1,65
1,00
214 g/h
118 g/h
71 g/h
0,70
0,40
0,40
20 30 35
Type of gas used Model conguration
4BURNERS
Rated thermal owrate
(kW)
Total rated
consumption
Air required (m
3
) for burning
1m
3
of gas
G20 20 mbar 1R - 2SR - 1AUX 7,30 695 l/h 9,52
G30 30 mbar 1R - 2SR - 1AUX 7,30 531 g/h 30,94
G31 30 mbar 1R - 2SR - 1AUX 7,30 521 g/h 23,80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6 W