DRYER DIMENSIONS
Most installations will require at least
5-inch clearance behind the dryer for the
dryer vent.
Location must be large enough to fully
open dryer door.
RECESSED AREA/CLOSET
INSTALLATION INSTRUCTIONS
Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.
The dryer must not be installed where it
can be exposed to water and/or weather.
• Proper operation of dryer cycles
requires temperatures above 45°F (at
lower temperatures, the dryer may not
shut off at the end of automatic cycles
and drying times will be extended).
• Check code requirements. Some
codes limit or do not permit installation
of clothes dryers in garages, closets,
mobile homes, or sleeping quarters.
Contact your local building inspector.
WARNING: To reduce the risk of
fire, this appliance MUST BE
EXHAUSTED OUTDOORS.
NOTE: No fuel-burning appliances may
be installed in the same closet as a dryer.
I °1°
t
FrontView
(DoorNotShown)
MINIMUM INSTALLATION SPACING
1" I
SideView
(DoorShown)
**48sq.in_.
minimum
ventilation
area
3"
3"
FrontView
(DoorWithVent)
* Additional clearances for wall, doorand floor moldings may be required. 0" clearance
isacceptable but notrecommended.
** Opening is minimum for closet door. Louvered doorwith equivalent air
openings is acceptable.
*** Additional space isneeded when external exhaustelbow isused. Can be0" clearance
when house exhausting is lined updirectly with dryer exhaust.
• in the above illustration, the installation
spacing is in inches and is the minimum
allowable.
• Additional spacing should be considered
for ease of installation and servicing.
• If closet door is installed, the minimum air
openings in top and bottom are
I0
required. Louvered doors with equivalent
air openings in top and bottom are
acceptable.
• All installations must be exhausted
outside. Use at least the minimum
dimensions indicated.