Kenmore 625383760 water softener

User Manual - Page 36

For 625383760.

PDF File Manual, 48 pages, Download pdf file

Loading ...
Loading ...
Loading ...
The faceplate timer (PWA) computer has a self-diagnostic
function for the electrical system, except put power and
water meter. The computer monitors electronic components
and circuits for correct operation. If a malfunction occurs, an
error code appears in the faceplate display.
The chart below shows the error codes that could appear,
and the possible problems for each code.
I- -t
rzn- _-]
FIG. 60
CODE
Errl, Err3, Err4
Err5
POSSIBLE PROBLEM
MOST LIKELY _ ]_-
wiring harness connections at switch and faceplate not connected / position switch inoperable / motor inoperable
faceplate timer (PWA)
LESS LIKELY
While an error code appears in the display, all faceplate
buttons are inoperable except the SELECT1 button.
SELECT1 remains operational so the service person can
make the MANUAL INITIATED ELECTRONIC DIAGNOS-
TICS (below) to further isolate the problem, and check the
water meter.
PROCEDURE FOR REMOVING ERROR CODE
FROM FACEPLATE:
1. Unplug transformer from outlet.
Plug in transformer.
Wait for 8 minutes.
2. Unplug transformer from outlet.
Correct problem.
Plug in transformer.
Wait for 8 minutes.
The error code will return ifthe problem was not corrected.
MANUAL INITIATED ELECTRONICS DIAGNOSTICS:
To enter diagnostics, press the SELECT1 button and hold
for three seconds. The display will show valve cycle posi-
tion, position switch status (open or closed), and turbine
operation. See Fig. 59.
TURBINE OPERATION: If no water is flowing through the
softener, the turbine indicator displays three zeros. When
water is flowing, the flow bar scrolls across the display, and
a 000 to 140 count repeats for each gallon of water passing
through the turbine. To check for positive operation of the
turbine if zeros are shown, open a nearby soft water faucet
and observe the turbine count and flow bar. If you don't get
a reading in the display, with faucet open, pull the sensor
from the valve outlet port. Pass a small magnet back and
forth in front of the sensor. You should get a reading in the
display. If you get a reading, unhook the in and out plumb-
ing and check the turbine for binding.
POSITION SWITCH STATUS: With the valve in service, or
any of the recharge cycles, the switch indicator will show
open, while the valve is rotating from one position to anoth-
er, the indicator will show the switch closed. A defect is
probable if indications vary from this pattern.
number of days
valve position indicator
since the last
I_i___ _v L, _yf regeneration
_"-_ I--H _____water meter
i/_Liq turbine count
/
position switch
indicator (open)
VALVE IN SERVICE POSITION
valve position indicator
\ minutes of fill
I_t__'_-_'_'_F,LLI--I_ _11m _ cycle remaining
i] ' q
14%- Iq 3_-I _ water meter
position switch
indicator (open)
VALVE IN RECHARGE POSITION (FILL, IN THIS EXAMPLE
valve position indicator
(Fill and Brine Flashing)
_!E minutes of brining
i___ II-I1-1_ L_ time (begins to count
_!_ _t_ I UU-- I down when valve
................| reaches brining
_1 position)
i _- IZI/JlJ _1", water meter
.... I turbine count
position switch
indicator (closed)
VALVE ROTATING FROM ONE RECHARGE POSITION TO
ANOTHER (FROM FILL TO BRINING IN THIS EXAMPLE)
FIG. 61
Questions? Call The Kenmore Water Line 1-800-426-9345
36
Loading ...
Loading ...
Loading ...