Instructions for the installer
14
4 ADJUSTMENT TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, unplug the
appliance from the mains.
The hob of the cooker is adjusted for use with either natural gas at a
pressure of 1.0 kPa. If used with other types of gas, you have to replace
the nozzles, then adjust the minimum flame on the gas taps. For nozzle
replacement and burner adjustment operate as described in the following
paragraph.
4.1 Replacement of nozzles on the hob
1. Remove the grids and all the caps and flame-spreader crowns;
2. Unscrew the burner nozzles with a 7 mm socket wrench;
3. Replace the nozzles according to the type of gas to be used (see
paragraph “3.2 Burner and nozzle characteristics table”).
4. Replace the burners in the correct position.