Readalldirectionscarefullybeforeyoubegin.
IMPORTANT:
Ifyouturntherefrigeratoronbeforethewaterlineis
connected,turntheicemakerOFE
Allinstallationsmustmeetlocalplumbingcoderequirements.
Usecoppertubingandcheckforleaks.Installcoppertubing
onlyinareaswherethehouseholdtemperatureswillremain
abovefreezing.
TOOLSNEEDED:Flat-bladescrewdriver,7_6"and1/2"open-end
wrenchesortwoadjustablewrenches,1/4"nutdriveranddrillbit,
handdrillorelectricdrill(properlygrounded).
NOTE:Yourrefrigeratordealerhasakitavailablewitha1/4"
(6.35mm)saddle-typeshutoffvalve,aunion,andcoppertubing.
Beforepurchasing,makesureasaddle-typevalvecomplieswith
yourlocalplumbingcodes.Donotuseapiercing-typeor3/16"
(4.76mm)saddlevalvewhichreduceswaterflowandclogsmore
easily.
WaterPressure
Acoldwatersupplywithwaterpressureofbetween30and
120psi(207-827kPa)isrequiredtooperatethewaterdispenser
andicemaker.Ifyouhavequestionsaboutyourwaterpressure,
callalicensed,qualifiedplumber.
ReverseOsmosisWaterSupply
Ifareverseosmosiswaterfiltrationsystemisconnectedtoyour
coldwatersupply,thewaterpressuretothereverseosmosis
systemneedstobeaminimumof40to60psi(276-414kPa).
Ifthewaterpressuretothereverseosmosissystemislessthan
40to60psi(276-414kPa):
Checktoseewhetherthesedimentfilterinthereverse
osmosissystemisblocked.Replacethefilterifnecessary.
Allowthestoragetankonthereverseosmosissystemtorefill
afterheavyusage.
Ifyouhavequestionsaboutyourwaterpressure,callalicensed,
qualifiedplumber.
Readalldirectionsbeforeyoubegin.
IMPORTANT:Ifyouturntherefrigeratoronbeforethewaterlineis
connected,turntheicemakerOFE
ConnecttoWaterLine
1. Unplugrefrigeratorordisconnectpower.
2. TurnOFFmainwatersupply.TurnONnearestfaucetlong
enoughtoclearlineofwater.
3. Locatea1/2"to11/4''(1.25cmto3.18cm)verticalcoldwater
pipeneartherefrigerator.
IMPORTANT:
Makesureitisacoldwaterpipe.
Horizontalpipewillwork,butdrillonthetopsideofthe
pipe,notthebottom.Thiswillhelpkeepwaterawayfrom
thedrillandnormalsedimentfromcollectinginthevalve.
Determinethelengthofcoppertubingyouneed.Measure
fromtheconnectiononthelowerleftrearofrefrigeratortothe
waterpipe.Add7ft(2.1m)toallowforcleaning.Use1/4"
(6.35mm)O.D.(outsidediameter)coppertubing.Besureboth
endsofcoppertubingarecutsquare.
Usingagroundeddrill,drilla1/4"holeinthecoldwaterpipe
youhaveselected.
A. Cold waterpipe E.Compression sleeve
B.Pipe clamp F.Shutoff valve
C.Copper tubing G.Packing nut
D. Compressionnut
6. Fasten the shutoff valve to the cold water pipe with the pipe
clamp. Be sure the outlet end is solidly in the 1/4"drilled hole in
the water pipe and that the washer is under the pipe clamp.
Tighten the packing nut. Tighten the pipe clamp screws
carefully and evenly so washer makes a watertight seal. Do
not overtighten or you may crush the copper tubing.
7. Slip the compression sleeve and compression nut on the
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression nut
onto outlet end with adjustable wrench. Do not overtighten.
8. Place the free end of the tubing in a container or sink, and turn
ON the main water supply. Flush the tubing until water is clear.
Turn OFF the shutoff valve on the water pipe. Coil the copper
tubing.
Connect to Refrigerator
1. Unplug refrigerator or disconnect power.
2. Attach the copper tube to the valve inlet using a compression
nut and sleeve as shown. Tighten the compression nut. Do not
overtighten.
3. Use the tube clamp on the back of the refrigerator to secure
the tubing to the refrigerator as shown. This will help prevent
damage to the tubing when the refrigerator is pushed back
against the wall.