Connective pipe and drainage installation
Connective pipe
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel. The pipe cover
must be kept as it may be used
when relocating the air conditioner
to any other place.
.
For the rear-right-hand and rear-left-
hand piping, install the piping as
shown in the sideward figure. Bend
the connective pipe to be laid at
a height of 1.69" or less from
the wall. Fix the end of the
connective pipe.
Pipe cover Pipe
(right) holder
piping
Indoor unit
outline
\
/
s
i
i
i
Pipe cover
(left)
piping
Connective
pipe
i -
,, _
Drainage
1. Run the drain hose sloping
downward. Do not install the drain
hose as illustrated sideward.
.
When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a
shield pipe, do not let the drain
hose slack.
Fastening the indoor Unit
1. Pass the piping through the hole in
the wall.
2. Put the upper claw at the back of
the indoor unit on the upper hook of
the installation plate, move the
indoor unit from side to side to see
that it is securely hooked.
Do not block
water flow
by a rise.
Do not block
water.flow
Do not put the end
n hose into water.
Upper hook \
Lower hook