54
3. HEALTH & SAFETY INFORMATION
IMPORTANT: EN149:2001+A1:2009 single-use respirators against solid and
liquid aerosols are classified according to one of three categories - FFP1,
FFP2 and FFP3.
Before reading the following information, please check the category to
which the respirator belongs - this is indicated on the packaging and on
the respirator.
3.1 APPLICATIONS
FFP1: Protection against non-toxic solid and liquid
aerosols (e.g. oil-mists) in concentrations up to
4 x MAC/OEL/TLV, [i.e. NPF = 4 ] or 4 x WEL,
[i.e. APF = 4].
FFP2: Protection against non-toxic and low-to-average
toxicity solid and liquid aerosols (e.g. oil-mists) in
concentrations up to 12 x MAC/OEL/TLV,
[i.e. NPF = 12] or 10 x WEL, [i.e. APF = 10].
FFP3: Protection against non-toxic, low-to-average
toxicity and high toxicity solid and liquid aerosols
(e.g. oil-mists) in concentrations up to 50 x
MAC/OEL/TLV,
[i.e. NPF = 50] or 20 x WEL, [i.e. APF = 20].
CHARCOAL FILTERS: 82484/82485 and 82561/82562 include charcoal
filters that offer added comfort by eliminating
fumes when welding or decorating respectively.
*NOTE: .noitartnecnoC elbissimdA mumixaM = CAM
OEL = Occupational Exposure Limit.
.eulaV timiL dlohserhT = VLT
.rotcaF noitcetorP lanimoN = FPN
.timiL erusopxE ecalpkroW = LEW
.rotcaF noitcetorP dengissA = FPA
4. FITTING INSTRUCTIONS
5. EXPLANATION OF SYMBOLS
4.2 FITTING INSTRUCTIONS
1. Hold the respirator in hand with the
nosepiece at your fingertips.
Allow headbands to hang freely below
hand.
2. Cup the respirator firmly against your
face with the nosepiece on the bridge
of your nose.
3. Stretch and pull the lower headband
over the head and position below your
ears. Stretch and pull the top headband
on the back of your head above your
ears.
* Respirators with adjustable headbands
only:
while maintaining the position of the
respirator, adjust tension by pulling lab
of each headband. (Tension may be
decreased by pushing out the back of
the buckle.)
4. Press soft nosepiece to conform snugly
around the nose.
5. (a) To test fit for respirator without
exhalation valve:
Cup both hands over the respirator
and exhale vigorously.
(b) To test fit for respirator with
exhalation valve:
Cup both hands over the respirator
and inhale sharply.
A negative pressure should be felt inside
respirator. If air flows around your nose,
tighten the nosepiece. If air leaks
around the edges, reposition the
headband for better fit.
*NOTE: Change respirator immediately if breathing becomes difficult or
respirator becomes damaged or distorted, or a proper face fit can not be
maintained.
Careful observance of these instructions is an important step in safe
respirator use.
WARNING:
1. Failure to follow all instructions and limitations on the use of this
product could reduce the effectiveness of respirator and result in
sickness or death.
2. A properly selected respirator is essential to protect your health.
Before using this respirator, consult an Industrial Hygienist or
Occupational Safety Professional to determine the suitability for your
intended use.
3. This product does not supply oxygen. Use only in adequately
ventilated areas containing sufficient oxygen to support life. Do not
use this respirator when oxygen concentration is less than 19%
4. Do not use when concentrations of contaminants are immediately
dangerous to health or life.
5. Do not use in explosive atmospheres.
6. Leave work area immediately and return to fresh air if (a) breathing
becomes difficult, or (b) dizziness or other distress occurs.
7. Facial hairs or beards and certain facial characteristics may reduce the
effectiveness of this respirator.
8. Never alter or modify this respirator in any way.
9. Only for single shift use. No maintenance necessary. Discard the used
respirator after single shift use.
10. Keep respirators in the display box away from direct sunlight until use.
Clear vision
Low profile design lets you see
where you are going and what
you are doing. Glasses or safety
goggles can be worn without
affecting vision.
Easy breathing/speaking
Contour fit
Soft metal nose piece adjusts
closely over bridge of nose.
Non-woven filter material fits
comfortably over facial features.
Maintenance free
After use dispose of
it safely.
Lightweight
+50°C
-5°C
<70%
yyyy/mm
NR
D
See user information
Temperature range of
storage condition.
Maximum relative humidity of storage condition.
End of shelf life. yyyy = Year; mm = Month.
This respirator is limited to
single shift use only (with a
maximum of 8 hours) and
shall not be re-used,
This respirator passes the
optional Dolomite clogging
test for more comfortable
breathing.
4.1 CHECK PRIOR TO USE
Inspect respirator, including any component parts, for holes, tears or
damage prior to use.
Should any damage be identified, DO NO USE IT. Get a new one.