Loading ...
Loading ...
Loading ...
EN
©2020 Hestan Commercial Corporation
11
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
G
ELECTRICAL
SUPPLY
LOCATION
FINISHED
FLOOR
E
COMBUSTIBLE
MATERIALS
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
W
V
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]
INSTALLATION CLEARANCES 30” WITH ISLAND TRIM
FRONT VIEW
1-1/2"
[3.8]
4"
[10.2]
11"
[27.9]
2-1/2"
[6.4]
7"
[17.8]
18"
[45.7]
12"
[30.5]
NOTES:
• SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
• APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
• “G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
• “E” IS ELECTRICAL SUPPLY ZONE.
• “W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
• “V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
RANGE MODEL
W
V (MIN)
KRD304 30” [76.2] 30” [76.2]
Loading ...
Loading ...
Loading ...