PRODUCT DATASHEETS
Standard Interior Water Filtration System Model WFI-NL200/NL200
(_ Tested and certified by NSF International against ANS!/NSP
Standard 42 for the reduction of Chlorine (Class t), Tasteand Odor.
Capacity : 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine, Taste/Odor N/A 2.0 mg/L N/A 0.02 mg/L N/A 99% 994715
Cyst Interior Water Filtration System Model WFI-NLC200/NLC200
Tested and certified by NSP International against ANSt/NSF Standard
42 for the reduction of Chlorine (Class t)Taste and Odor and against
ANSt/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
Substance Reduction U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Aesthetic Effects MCL Influent Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor N/A 1.9 mg/L N/A 0.06 mg/L N/A 97% 994707
Particulate N/A 108,667/mL _ N/A 45/mL N/A 99.96% 994711
Contaminant U.S. EPA Average Maximum Average Minimum % Average % NSF Test
Reduction MCL Influent Effluent Effluent Reduction Reduction Number
Cyst 99.95% _ 157,750/mL 55/mL 1.0/mL 99.9987% 99.9996% 994710
Turbidity N/A 26 NTU 0.5 NTU 0.1 NTU 98.9% 99.5% 994710
Lead: @ pH 6,5 0.015 mg/L 0.160 mg/L "_ 0.011 mg/L 0.001 mg/L 93.5% 99.4% 994708
Lead: @ pH 8.5 0.015 mg/L 0.158 mg/L _ 0.011 mg/L 0.001 mg/L 92.1% 99.3% 994709
It is essential that operational, maintenance, and filter
replacement requirements be carried out for this product to
perform as advertised.
Model NL200 Change cartridge at least every 6-9 months.
Use replacement cartridge NL200, part# 8171413. 2000
suggested retail price of $29.95 U.S.A./S39.95 Canada.
Model NLC200 Change the cartridge at least every 6-9
months. Use replacement cartridge NLC200, part# 8171414.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected water that may contain filterable cysts.
Refer to the "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8 ° C)
*Test requirement is at least 100,000 particles/ml of AC Fine Test Dust.
**Cyst performance is % reduction based on NSF Standard 53.
**_Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply.
Performance may vary based on local water conditions.
_P NSF is a registered trademark of NSF International.