Smeg B901GMXI9 Cooker with Gas Hob 90x60 cm

User Manual - Page 37

For B901GMXI9.

PDF File Manual, 46 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation
85
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 3.0 4.0
Nozzle diameter (1/100 mm)
50 65 85 100
Pre-chamber (printed on nozzle)
----
Reduced flow rate (W)
400 500 800 1400
Rated flow rate G30 (g/h)
73 131 218 291
Rated flow rate G31 (g/h)
71 129 214 286
8 LPG G30/31
AUX SR R UR2
Rated heating capacity (kW)
1.1 1.9 3.0 4.1
Nozzle diameter (1/100 mm)
50 65 81 95
Pre-chamber (printed on nozzle)
----
Reduced flow rate (W)
450 550 900 1400
Rated flow rate G30 (g/h)
80 138 218 298
Rated flow rate G31 (g/h)
79 136 214 293
9 LPG G30/31
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 3.0 4.1
Nozzle diameter (1/100 mm)
43 58 74 80
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (F4)
Reduced flow rate (W)
400 500 1000 1500
Rated flow rate G30 (g/h)
73 131 218 298
Rated flow rate G31 (g/h)
71 129 214 293
10 Town gas G110
AUX SR R UR2
Rated heating capacity (kW)
1.0 1.8 2.8 3.4
Nozzle diameter (1/100 mm)
145 185 260 340
Pre-chamber (printed on nozzle)
(/8) (/2) (/3) 0190
Reduced flow rate (W)
400 500 800 1200
Loading ...
Loading ...
Loading ...